Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures
Europace · 30.08.2024 · 26 (9)
DOI: 10.1093/europace/euae221 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Europace, online erschienen am 21.08.2024. Verfasst von Marc D Lemoine und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Pulmonary Veins, Cryosurgery, Atrial Fibrillation, Recurrence. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biosense Webster, Farapulse, Research Promotion Fund of the Faculty of Medicine.
Abstract (Originalsprache)
Aims
Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI. Methods and result A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation.
Conclusion
During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Germany.
- Institute of Cardiovascular Sciences, University of Birmingham, Birmingham, UK.
ORCID-Profile: Marc D Lemoine, Julius Obergassel, Sandro Jaeckle, Moritz Nies, Jan Rieß, Ilaria My, Laura Rottner, Fabian Moser, Djemail Ismaili, Feifan Ouyang, Paulus Kirchhof, Andreas Rillig, Andreas Metzner
Förderung
- Biosense Webster
- Farapulse
- Research Promotion Fund of the Faculty of Medicine
- Abbott
- German Heart Foundation
- University of Hamburg
- German Federal Ministry of Education and Research
- German Research Foundation
Zitieren
APA
Lemoine, M. D., Obergassel, J., Jaeckle, S., Nies, M., Taraba, S., Mencke, C., Rieß, J., My, I., Rottner, L., Moser, F., Ismaili, D., Reißmann, B., Ouyang, F., Kirchhof, P., Rillig, A., & Metzner, A. (2024). Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures. Europace, 26(9). https://doi.org/10.1093/europace/euae221
Vancouver
Lemoine MD, Obergassel J, Jaeckle S, Nies M, Taraba S, Mencke C, et al. Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures. Europace. 2024;26(9). doi:10.1093/europace/euae221
BibTeX
@article{Lemoine2024,
author = {Lemoine, Marc D and Obergassel, Julius and Jaeckle, Sandro and Nies, Moritz and Taraba, Sophia and Mencke, Celine and Rieß, Jan and My, Ilaria and Rottner, Laura and Moser, Fabian and Ismaili, Djemail and Reißmann, Bruno and Ouyang, Feifan and Kirchhof, Paulus and Rillig, Andreas and Metzner, Andreas},
title = {Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures},
journal = {Europace},
year = {2024},
volume = {26},
number = {9},
doi = {10.1093/europace/euae221}
}
EUVIMED