Fachartikel in der Zeitschrift Heart Rhythm, 2023. Verfasst von Juan Carlos Diaz und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Clinica Las Vegas, Universidad CES Medical School, Medellin, Colombia. Elec…. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Heart Diseases, Pacemaker, Artificial, Prosthesis-Related Infections. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Infection is the most dreaded complication of cardiac implantable electronic devices (CIEDs), particularly in patients undergoing high-risk procedures (eg, generator change, device upgrade, lead/pocket revision). OBJECTIVE: The purpose of this study was to describe the impact of chlorhexidine gluconate (CHG) pocket lavage in high-risk procedures. METHODS: Patients from a prospective multicenter registry undergoing high-risk procedures were included. CHG lavage was performed by irrigating the generator pocket with 20 cc of 2% CHG without alcohol followed by and normal saline (NS) irrigation. Only NS irrigation was performed in the comparison group. The primary efficacy outcome was CIED-related infection at 12 months. The primary safety outcome was any CHG-associated adverse event. The secondary outcome was CIED infection during long-term follow-up. Propensity score matching (PSM) analysis was performed for the primary efficacy outcome. RESULTS: A total of 1504 patients were included. At 12-month follow-up, the primary efficacy outcome occurred in 4 of 904 CHG (0.4%) and 14 of 600 NS (2.3%) subjects (log-rank P = .005). On multivariate analysis, the use of CHG irrigation was associated with a lower risk of infection at 1-year follow-up (Cox proportional hazard ratio [HR] 0.138; 95% confidence interval [CI] 0.04-0.45; P = .001). This effect persisted during long-term follow-up. PSM demonstrated a significant reduction in CIED-related infection for the CHG group (0.2% vs 2.5%; Cox proportional HR 0.08; 95% CI 0.01-0.59; P = .014). No adverse events were associated with the use of CHG. CONCLUSION: CHG lavage during high-risk procedures was associated with a reduction in CIED-related infections without any adverse events reported. The benefits of CHG lavage were observed even during long-term follow up and in PSM analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Clinica Las Vegas, Universidad CES Medical School, Medellin, Colombia. Electronic address: jeromero@bwh.harvard.edu.
- Department of Cardiology, Smidt Heart Institute, Cedars-Sinai, Los Angeles, California.
- Universidad CES School of Medicine, Medellin, Colombia.
- Cardiac Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia.
- Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Department of Medicine, Clinica Las Americas, Medellin, Colombia.
- Cardiac Arrhythmia and Electrophysiology Service, Hospital Pablo Tobon, Medellin, Colombia.
Zitieren
APA
Diaz, J. C., Braunstein, E. D., Cañas, F., Duque, M., Marín, J. E., Aristizabal, J., Niño, C. D., Bastidas, O., Hoyos, C., Steiger, N. A., Matos, C. D., Sauer, W. H., & Romero, J. E. (2023). Chlorhexidine gluconate pocket lavage to prevent cardiac implantable electronic device infection in high-risk procedures. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2023.08.015
Vancouver
Diaz JC, Braunstein ED, Cañas F, Duque M, Marín JE, Aristizabal J, et al. Chlorhexidine gluconate pocket lavage to prevent cardiac implantable electronic device infection in high-risk procedures. Heart Rhythm. 2023. doi:10.1016/j.hrthm.2023.08.015
BibTeX
@article{Diaz2023,
author = {Diaz, Juan Carlos and Braunstein, Eric D and Cañas, Felipe and Duque, Mauricio and Marín, Jorge Eduardo and Aristizabal, Julian and Niño, Cesar Daniel and Bastidas, Oriana and Hoyos, Carolina and Steiger, Nathaniel A and Matos, Carlos D and Sauer, William H and Romero, Jorge E},
title = {Chlorhexidine gluconate pocket lavage to prevent cardiac implantable electronic device infection in high-risk procedures},
journal = {Heart Rhythm},
year = {2023},
doi = {10.1016/j.hrthm.2023.08.015}
}
EUVIMED