Device Infection Using Chlorhexidine Irrigation vs an Antibacterial Envelope
JACC: Clinical Electrophysiology · 2026-06 · 12 (6) · 1393-1402
DOI: 10.1016/j.jacep.2026.01.035 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift JACC: Clinical Electrophysiology, 2026-06. Verfasst von Jorge Eduardo Marin und 19 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Department of Medicine, Clinica Las Americas, Medellín, Colombia; Universid…. Hauptthemen laut MEDLINE: Chlorhexidine, Anti-Bacterial Agents, Prosthesis-Related Infections, Therapeutic Irrigation. Die Arbeit nennt 34 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND Cardiac implantable electronic device (CIED) infection represents a significant cause of morbidity and increased health care costs in patients undergoing high-risk procedures. OBJECTIVE This study sought to describe the incidence of infection using two prevention strategies: chlorhexidine gluconate (CHG) pocket irrigation vs antibacterial envelope (ABE). METHODS In this retrospective observational study, patients undergoing high-risk CIED interventions (generator change, device upgrade, lead/pocket revision, cardiac resynchronization device implantation) between 2018 and 2024, in whom either CHG irrigation or ABE was used, were included. Propensity score matching using baseline and procedural characteristics (age, sex, previous infection, intervention within 60 days, type of device, type of intervention, PADIT [Prevention of Arrythmia Device Infection Trial] score, antibiotic used) was performed. RESULTS A total of 1,749 patients (median age 73 years [Q1-Q3: 63-81 years], female 42%; CHG: n = 1,118) were included. After a median follow-up of 459 days (Q1-Q3: 192-852 days), there were no statistically significant differences in the risk of CIED-related infection (0.8% vs 0.8%; HR: 0.89; 95% CI: 0.3-2.66; log-rank P = 0.83) between the CHG and ABE groups. After propensity score matching, a total of 714 patients, without statistically significant differences in baseline characteristics, were analyzed. There were no significant differences in the risk of CIED-related infection (1.1% vs 1.1%; HR: 0.97; 95% CI: 0.24-3.86, log-rank P = 0.96). No adverse events associated with CHG irrigation occurred. CONCLUSIONS In high-risk procedures, CHG irrigation resulted in a similar risk of CIED-related infection as treatment with an ABE, without any adverse events. The lower cost of CHG and widespread availability could result in more patients being treated, thus extending the benefits to patients with a lower risk of infection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Department of Medicine, Clinica Las Americas, Medellín, Colombia; Universidad CES School of Medicine, Medellín, Colombia.
- Clínica Cardioinfantil, Bogotá, Colombia.
- Universidad de la Sabana, Bogotá, Colombia.
- Universidad CES School of Medicine, Medellín, Colombia.
- Clinica Shaio, Bogotá, Colombia.
- Clínica Cardioinfantil, Bogotá, Colombia; Universidad de la Sabana, Bogotá, Colombia.
Zitieren
APA
Marin, J. E., Tapias, C., Santacruz-Pacheco, D., Rojas, D., Olaya, A., Giraldo, S., Bautista, W., Saenz, L. C., Rosas-Andrade, J. F., Velasco, V. M., Betancourt-Rodríguez, J. F., Camargo-Ballestas, J. M., Mosquera, A., Florez, S., Aristizabal, J. M., Nino, C. D., Duque, M., Ruiz, L. M., Bastidas, O., & Diaz, J. C. (2026). Device Infection Using Chlorhexidine Irrigation vs an Antibacterial Envelope. JACC: Clinical Electrophysiology, 12(6), 1393-1402. https://doi.org/10.1016/j.jacep.2026.01.035
Vancouver
Marin JE, Tapias C, Santacruz-Pacheco D, Rojas D, Olaya A, Giraldo S, et al. Device Infection Using Chlorhexidine Irrigation vs an Antibacterial Envelope. JACC: Clinical Electrophysiology. 2026;12(6):1393-1402. doi:10.1016/j.jacep.2026.01.035
BibTeX
@article{Marin2026,
author = {Marin, Jorge Eduardo and Tapias, Carlos and Santacruz-Pacheco, David and Rojas, Diego and Olaya, Alejandro and Giraldo, Santiago and Bautista, William and Saenz, Luis Carlos and Rosas-Andrade, Jaime F and Velasco, Víctor Manuel and Betancourt-Rodríguez, Juan Felipe and Camargo-Ballestas, Juan Manuel and Mosquera, Andres and Florez, Sara and Aristizabal, Julian Miguel and Nino, Cesar Daniel and Duque, Mauricio and Ruiz, Luis Miguel and Bastidas, Oriana and Diaz, Juan Carlos},
title = {Device Infection Using Chlorhexidine Irrigation vs an Antibacterial Envelope},
journal = {JACC: Clinical Electrophysiology},
year = {2026},
volume = {12},
number = {6},
pages = {1393--1402},
doi = {10.1016/j.jacep.2026.01.035}
}
EUVIMED