EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Pulmonary vein isolation using a novel balloon-in-basket pulsed field ablation system: The Lübeck how-to protocol

Roland Richard Tilz, Sascha Hatahet, Charlotte Eitel, Sorin Popescu, Behnam Subin, Karl-Heinz Kuck, Roman Mamaev, Jan-Per Wenzel

Heart Rhythm O2 · 2026-06 · 7 (6) · 1042-1052

DOI: 10.1016/j.hroo.2026.02.022 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Heart Rhythm O2, 2026-06. Verfasst von Roland Richard Tilz und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Single-shot pulsed field ablation (PFA) is increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). Although balloon-in-basket (BiB)-PFA system integrates ablation and mapping into a single catheter, standardized procedural workflows remain limited.

Objective

This study aimed to describe a standardized, step-by-step workflow for AF ablation using the BiB-PFA system and evaluate procedural performance, acute safety, and the learning curve in clinical practice.

Methods

This prospective, single-center study included 40 consecutive patients undergoing index PVI using the BiB-PFA system at a tertiary high-volume electrophysiology center. Procedures followed standardized protocol including balloon preparation, ultrasound-guided access, fluoroscopy-guided transseptal puncture, selective pulmonary vein (PV) angiography, and a structured 2-step ablation approach for each vein. Posterior wall ablation (PWA) was performed in selected patients. Procedural metrics and acute complications were analyzed descriptively.

Results

Patients were 64.5 years old (56.5, 73.3); 41% were female, and 57.5% had nonparoxysmal AF. The median procedural duration was 41.5 minutes (35.0, 59.0), left atrial dwell time 27.5 minutes (25.0, 36.0), and BiB dwell time 23.0 minutes (20.0, 25.8). A median of 4 applications per PV was used. Reduced-energy delivery was required in 30% of right inferior and 25% of right superior PV. PWA was performed in 35% of patients using a median of 5 applications. No major intraprocedural complication occurred. The mean procedural duration decreased from 50.0 minutes (38.0, 60.5) in the first 10 cases to 34.5 minutes (31.5, 52.0) in the last 10 cases (P = .059).

Conclusion

A standardized BiB-PFA workflow enables efficient, safe, and reproducible PVI with optional PWA and can be rapidly implemented during early operator experience.

Schlagwörter

Stichwörter der Autor:innen

Atrial fibrillationBalloon-in-basketLearning curvePulmonary vein isolationPulsed field ablationWorkflow

Autor:innen und Institutionen

  • Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
  • German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany.

Zitieren

APA

Tilz, R. R., Hatahet, S., Eitel, C., Popescu, S., Subin, B., Kuck, K. H., Mamaev, R., & Wenzel, J. P. (2026). Pulmonary vein isolation using a novel balloon-in-basket pulsed field ablation system: The Lübeck how-to protocol. Heart Rhythm O2, 7(6), 1042-1052. https://doi.org/10.1016/j.hroo.2026.02.022

Vancouver

Tilz RR, Hatahet S, Eitel C, Popescu S, Subin B, Kuck KH, et al. Pulmonary vein isolation using a novel balloon-in-basket pulsed field ablation system: The Lübeck how-to protocol. Heart Rhythm O2. 2026;7(6):1042-1052. doi:10.1016/j.hroo.2026.02.022

BibTeX
@article{Tilz2026,
  author = {Tilz, Roland Richard and Hatahet, Sascha and Eitel, Charlotte and Popescu, Sorin and Subin, Behnam and Kuck, Karl-Heinz and Mamaev, Roman and Wenzel, Jan-Per},
  title = {Pulmonary vein isolation using a novel balloon-in-basket pulsed field ablation system: The Lübeck how-to protocol},
  journal = {Heart Rhythm O2},
  year = {2026},
  volume = {7},
  number = {6},
  pages = {1042--1052},
  doi = {10.1016/j.hroo.2026.02.022}
}
Kostenlos starten →