EUVIMEDEUVIMED entdecken
Crossref

A finite element analysis to assess tibial bone fracture in malleolar regions following total ankle replacement: Influences of implant designs and implant-bone interfacial conditions

Govind Upadhyay, Jyoti, Minku, Gaurav Kumar Sharma, Rajesh Ghosh

Foot and Ankle Surgery · 2025

DOI: 10.1016/j.fas.2025.01.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Foot and Ankle Surgery, 2025. Verfasst von Govind Upadhyay und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biomechanics Research Laboratory, School of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175075,…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Ankle, Prosthesis Design, Tibial Fractures, Ankle Fractures. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Indian Institute of Technology Mandi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Tibial bone fractures in the malleolar regions are a major concern during the early postoperative period of total ankle replacement (TAR), affecting patient outcomes such as stability and recovery. Design, placement, and anatomic misalignment of implant components can contribute to malleolar fractures. The aim of this study is to understand the influence of implant design features, including keel, peg, stem, and bar type design, and bone-implant interfacial conditions on malleolar fracture following TAR. METHODS: Three-dimensional finite element (FE) models were generated for the intact and implanted tibia bone using computer tomography (CT) scan data. In the present study, both bonded (fully osseointegration) and debonded (non-osseointegration) implant-bone interface conditions were considered. The proximal part of the tibia was fixed. Finite element models of the intact and implanted tibia were solved for three distinct loading situations that correspond to three ankle positions throughout the gait cycle (GC). The influences of implant design and implant-bone interface conditions on malleolar fracture were examined by evaluating stress distribution in tibia bone post-implantation. RESULTS: Finite element (FE) analysis revealed that for the medial region, the tibia bone stress elevated to 10 MPa for the medial keel type design, indicating a possible fracture along the medial region. The risk of a medial malleolar fracture is highest for the medial keel type implant design compared to other designs. The bars, central keel, and stem type TAR implant designs also elevate stress on both the medial and lateral regions of the tibia bone. In the case of fully osseointegrated implant-bone interface conditions, the stress is slightly higher than in the case of non-osseointegrated implant-bone interfacial conditions. CONCLUSION: The study highlights the potential influence of specific implant designs on malleolar fracture. The current findings are crucial for designing new implants to mitigate tibial bone fracture risks and improve TAR outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, AnkleProsthesis DesignTibial FracturesAnkle FracturesJoint ProsthesisBone-Implant InterfaceHumansFinite Element AnalysisTomography, X-Ray ComputedOsseointegrationBiomechanical PhenomenaImaging, Three-Dimensional

Stichwörter der Autor:innen

Bone fractureBone stressFinite element analysisImplant designTotal ankle replacement

Autor:innen und Institutionen

  • Biomechanics Research Laboratory, School of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175075, India. Electronic address: s22034@students.iitmandi.ac.in.
  • Biomechanics Research Laboratory, School of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175075, India. Electronic address: d19006@students.iitmandi.ac.in.
  • Biomechanics Research Laboratory, School of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175075, India. Electronic address: minkuarora110@gmail.com.
  • Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), Bilaspur, Himachal Pradesh 174037, India. Electronic address: dr.gaurav.ortho@aiimsbilaspur.edu.in.
  • Biomechanics Research Laboratory, School of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175075, India. Electronic address: rajesh@iitmandi.ac.in.

Förderung

  • Indian Institute of Technology Mandi

Zitieren

APA

Upadhyay, G., Jyoti, Minku, Sharma, G. K., & Ghosh, R. (2025). A finite element analysis to assess tibial bone fracture in malleolar regions following total ankle replacement: Influences of implant designs and implant-bone interfacial conditions. Foot and Ankle Surgery. https://doi.org/10.1016/j.fas.2025.01.003

Vancouver

Upadhyay G, Jyoti, Minku, Sharma GK, Ghosh R. A finite element analysis to assess tibial bone fracture in malleolar regions following total ankle replacement: Influences of implant designs and implant-bone interfacial conditions. Foot and Ankle Surgery. 2025. doi:10.1016/j.fas.2025.01.003

BibTeX
@article{Upadhyay2025,
  author = {Upadhyay, Govind and Jyoti and Minku and Sharma, Gaurav Kumar and Ghosh, Rajesh},
  title = {A finite element analysis to assess tibial bone fracture in malleolar regions following total ankle replacement: Influences of implant designs and implant-bone interfacial conditions},
  journal = {Foot and Ankle Surgery},
  year = {2025},
  doi = {10.1016/j.fas.2025.01.003}
}
Kostenlos starten →