Feasibility of using a novel optically filtered monochromatic portable X-ray fluorescence (MXRF) to quantify lead in wild bird bones

Kolawole E Adesina, James A DiNatale, Stephanie S Costa, Bethany Faber, Todd E Katzner, Sunny Cooper, Kristin Dean, Michael Martin, Brian P Jackson, Thomas R Grier, Aaron J Specht

Environmental Research · 2026-09 · 306 · 125261

DOI: 10.1016/j.envres.2026.125261 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Research, 2026-09. Verfasst von Kolawole E Adesina und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Sciences, Purdue University, West Lafayette, IN, 47906, USA. Hauptthemen laut MEDLINE: Lead, Spectrometry, X-Ray Emission, Bone and Bones, Environmental Monitoring. Die Arbeit nennt 74 Literaturangaben. Gefördert von: JPB Foundation, National Institute for Occupational Safety and Health Atlanta, Harvard T H Chan School of Public Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lead (Pb) threatens wildlife and humans through neurological, cardiovascular, and renal damage. Conventional tissue Pb assessment relies on costly wet-lab methods such as inductively coupled plasma mass spectrometry (ICP-MS). Monochromatic X-ray fluorescence (MXRF) enables rapid, non-destructive, field-deployable Pb detection with lower detection limits than prior portable XRF systems. We evaluated the feasibility, calibration, attenuation correction, and ICP-MS agreement of a doubly curved crystal (DCC)-enhanced MXRF (X-ray Optical Systems, East Greenbush, NY) for bone Pb quantification in American black vultures (Coragyps atratus). Thirty-eight bird bones were analyzed ex vivo (n = 19 femurs; n = 19 tarsometatarsi[TMT]) using an HD Mobile XRF (1-mm spot; Mo anode; silicon drift detector; 200s). Calibration used Pb-doped plaster phantoms (0-100 ppm) with polymethyl methacrylate soft-tissue equivalents (0-5 mm). Spectra (10.0-13.6 keV) were fit with a Gaussian Pb-peak on a smooth background and Compton sideband normalization. Matched samples were quantified by ICP-MS. Agreement was assessed by ordinary least squares (OLS) regression, Pearson r, Passing-Bablok, intraclass correlation coefficient (ICC; two-way, absolute), reduced major axis (RMA) regression, and Bland-Altman analysis. Detection limits were obtained using blank-and-slope calibration and 30 repeated measurements on two bones. Signal attenuated exponentially, limiting reliable quantification beyond ∼3 mm soft tissue. Calibration was linear (counts vs. ppm: R2 = 0.996; phantom nominal vs. MXRF: R2 = 0.994). MXRF agreed closely with ICP-MS (femur r = 0.959, ICC = 0.933; TMT r = 0.962, ICC = 0.953). Bland-Altman mean biases were small (femur: -1.73 μg/g; TMT: -0.42 μg/g) without proportional bias. Passing-Bablok slopes approached unity (≈0.86-0.96) with small intercepts. Practical DLs were 1.79 μg/g(femur) and 0.80 μg/g(TMT) and are the relevant benchmarks for biological measurement; the calibration-derived instrumental DL of 0.03 μg/g at 200 s is an idealized zero-matrix value. This DCC-based MXRF delivered rapid, non-destructive bone Pb estimates concordant with ICP-MS and low DLs. Attenuation correction and fixed geometry support ex vivo Pb surveillance, carcass triage, and program evaluation in birds, with extension to other species, including humans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LeadSpectrometry, X-Ray EmissionBone and BonesEnvironmental MonitoringBirdsEnvironmental PollutantsAnimalsFeasibility StudiesPortable X-RayCalibration

Stichwörter der Autor:innen

BoneDoubly curved crystal (DCC)Monochromatic X-ray fluorescence (MXRF)Optical-enabled systemSpectrometrylead (Pb)

Substanzen

LeadEnvironmental Pollutants

Autor:innen und Institutionen

  • School of Health Sciences, Purdue University, West Lafayette, IN, 47906, USA.
  • U.S. Geological Survey, Forest and Rangeland Ecosystem Science Center, Boise, ID, USA; School of Natural Resources and the Environment, West Virginia University, Morgantown, WV, USA.
  • Carolina Raptor Center, Huntersville, NC, USA.
  • North Carolina Department of Agriculture and Consumer Services, Raleigh, NC, USA.
  • Dartmouth College, Hanover, NH, USA.
  • School of Health Sciences, Purdue University, West Lafayette, IN, 47906, USA; Harvard T.H. Chan School of Public Health, Boston, MA, 02115, USA. Electronic address: aspecht@purdue.edu.

Förderung

  • JPB Foundation
  • National Institute for Occupational Safety and Health Atlanta
  • Harvard T H Chan School of Public Health
  • U.S. Geological Survey
  • U.S. Fish and Wildlife Service

Zitieren

APA

Adesina, K. E., DiNatale, J. A., Costa, S. S., Faber, B., Katzner, T. E., Cooper, S., Dean, K., Martin, M., Jackson, B. P., Grier, T. R., & Specht, A. J. (2026). Feasibility of using a novel optically filtered monochromatic portable X-ray fluorescence (MXRF) to quantify lead in wild bird bones. Environmental Research, 306, 125261. https://doi.org/10.1016/j.envres.2026.125261

Vancouver

Adesina KE, DiNatale JA, Costa SS, Faber B, Katzner TE, Cooper S, et al. Feasibility of using a novel optically filtered monochromatic portable X-ray fluorescence (MXRF) to quantify lead in wild bird bones. Environmental Research. 2026;306:125261. doi:10.1016/j.envres.2026.125261

BibTeX
@article{Adesina2026,
  author = {Adesina, Kolawole E and DiNatale, James A and Costa, Stephanie S and Faber, Bethany and Katzner, Todd E and Cooper, Sunny and Dean, Kristin and Martin, Michael and Jackson, Brian P and Grier, Thomas R and Specht, Aaron J},
  title = {Feasibility of using a novel optically filtered monochromatic portable X-ray fluorescence (MXRF) to quantify lead in wild bird bones},
  journal = {Environmental Research},
  year = {2026},
  volume = {306},
  pages = {125261},
  doi = {10.1016/j.envres.2026.125261}
}
Kostenlos starten →