In situ measurements of heavy metal distributions in soil columns during miscible displacement experiments using portable X‐ray fluorescence
Journal of Environmental Quality · 2026
DOI: 10.1002/jeq2.70103 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Quality, 2026. Verfasst von Joshua T Padilla und 3 weiteren Autor:innen. Beteiligte Einrichtung: USDA-ARS Coastal Plains Soil, Water and Plant Research Center, Florence, South Carolina, USA. Hauptthemen laut MEDLINE: Spectrometry, X-Ray Emission, Metals, Heavy, Soil, Soil Pollutants. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Miscible displacement experiments traditionally rely on measured effluent concentrations of a given chemical with time to characterize its transport through soils. Time‐dependent distributions of heavy metals within a soil column are difficult to obtain and are typically ignored. We developed a methodology for measuring time‐dependent distributions of zinc (Zn) and nickel (Ni) within soil using a Kapton film (KF) column and portable X‐ray fluorescence (pXRF) device. Matrix‐matched calibrations were developed for each matrix/solute combination based on linear regressions between known and pXRF‐measured Zn and Ni concentrations within the KF column. We assessed the accuracy of pXRF measurements using mass balance calculations; our matrix‐matched calibration significantly reduced cumulative mass balance errors for three of the four experimental datasets. We compared pXRF‐measured Zn or Ni concentrations at various column lengths to those predicted by a single‐site, nonlinear kinetic model. The model accurately predicted the timing of peak Zn or Ni concentrations at each column length in reference sand and Wolfpen soil; however, overall model performance was element‐ and matrix‐dependent. Our results demonstrate that use of a KF column and pXRF device enables the acquisition of time‐dependent distributions of Zn or Ni distributions in soil columns. We expect that this approach will be appropriate for other heavy metals, particularly those with higher energy fluorescent X‐rays (atomic number > 30) where less X‐ray attenuation by the KF column and soil matrix is expected. Accurate descriptions of heavy metal distributions with column length and time will provide an additional metric to validate reactive transport models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- USDA-ARS Coastal Plains Soil, Water and Plant Research Center, Florence, South Carolina, USA.
- Soils and Water Use Department, Agricultural and Biological Research Institute, National Research Centre, Cairo, Egypt.
- Natural Resource Ecology Laboratory, Colorado State University, Fort Collins, Colorado, USA.
- School of Plant, Environmental and Soil Sciences, Louisiana State University, Baton Rouge, Louisiana, USA.
ORCID-Profile: Joshua T Padilla, Tamer A Elbana
Zitieren
APA
Padilla, J. T., Elbana, T. A., Sun, W., & Selim, H. M. (2026). In situ measurements of heavy metal distributions in soil columns during miscible displacement experiments using portable X‐ray fluorescence. Journal of Environmental Quality. https://doi.org/10.1002/jeq2.70103
Vancouver
Padilla JT, Elbana TA, Sun W, Selim HM. In situ measurements of heavy metal distributions in soil columns during miscible displacement experiments using portable X‐ray fluorescence. Journal of Environmental Quality. 2026. doi:10.1002/jeq2.70103
BibTeX
@article{Padilla2026,
author = {Padilla, Joshua T and Elbana, Tamer A and Sun, Wenguang and Selim, H Magdi},
title = {In situ measurements of heavy metal distributions in soil columns during miscible displacement experiments using portable X‐ray fluorescence},
journal = {Journal of Environmental Quality},
year = {2026},
doi = {10.1002/jeq2.70103}
}
EUVIMED