Building parameters linked with indoor transmission of SARS-CoV-2
Environmental Research · 2023-12 · 238 · 117156
DOI: 10.1016/j.envres.2023.117156 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Environmental Research, 2023-12. Verfasst von Jacqueline Horne und 7 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada. Hauptthemen laut MEDLINE: COVID-19, Air Pollution, Indoor. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 87 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
The rapid spread of Coronavirus Disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has emphasized the importance of understanding and adapting to the indoor remediation of transmissible diseases to decrease the risk for future pandemic threats. While there were many precautions in place to hinder the spread of COVID-19, there has also been a substantial increase of new research on SARS-CoV-2 that can be utilized to further mitigate the transmission risk of this novel virus. This review paper aims to identify the building parameters of indoor spaces that could have considerable influence on the transmission of SARS-CoV-2. The following building parameters have been identified and analyzed, emphasizing their link with the indoor transmission of SARS-CoV-2: temperature and relative humidity, temperature differences between rooms, ventilation rate and access to natural ventilation, occupant density, surface type and finish, airflow direction and speed, air stability, indoor air pollution, central air conditioning systems, capacity of air handling system and HVAC filter efficiency, edge sealing of air filters, room layout and interior design, and compartmentalization of interior space. This paper also explains the interactions of SARS-CoV-2 with indoor environments and its persistence. Furthermore, the modifications of the key building parameters have been discussed for controlling the transmission of SARS-CoV-2 in indoor spaces. Understanding the information provided in this paper is crucial to develop effective health and safety measures that will aid in infection prevention.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada.
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada. Electronic address: msafiuddin@georgebrown.ca.
- Sysconverge Inc., 7030 Woodbine Avenue, Suite 500, Markham, ON L3R 6G2, Canada.
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Horne, J., Dunne, N., Singh, N., Safiuddin, M., Esmaeili, N., Erenler, M., Ho, I., & Luk, E. (2023). Building parameters linked with indoor transmission of SARS-CoV-2. Environmental Research, 238, 117156. https://doi.org/10.1016/j.envres.2023.117156
Vancouver
Horne J, Dunne N, Singh N, Safiuddin M, Esmaeili N, Erenler M, et al. Building parameters linked with indoor transmission of SARS-CoV-2. Environmental Research. 2023;238:117156. doi:10.1016/j.envres.2023.117156
BibTeX
@article{Horne2023,
author = {Horne, Jacqueline and Dunne, Nicholas and Singh, Nirmala and Safiuddin, Md and Esmaeili, Navid and Erenler, Merve and Ho, Ian and Luk, Edwin},
title = {Building parameters linked with indoor transmission of SARS-CoV-2},
journal = {Environmental Research},
year = {2023},
volume = {238},
pages = {117156},
doi = {10.1016/j.envres.2023.117156}
}
EUVIMED