Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Jooyeon Park und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Seoul National University, Seoul, Korea. Hauptthemen laut MEDLINE: Disinfection, Ventilation, Ultraviolet Rays, COVID-19. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Medical Device Development Fund, National Research Foundation of Korea, Institute of Engineering Research, Seoul National University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Since the COVID-19 pandemic, there has been persistent emphasis on the importance of indoor air disinfection and ventilation in isolation units in the hospital environment. Nevertheless, no optimal and concrete disinfection protocol has been proposed to inactivate the viruses as quickly as possible. In this study, we experimentally evaluated various ventilation and disinfection protocols based on the combination of negative-pressure ventilation, ultraviolet (UV) light illumination, and Hypochlorous acid (HOCl) spray against three active virus species in a 3.5 cubic meters isolation unit. This small-size unit has gained attention during the pandemic due to the high demand for compact mobile laboratory systems capable of rapid disease diagnosis. In accordance with the WHO laboratory biosafety guidance, which states that all enclosed units where diagnostic work is conducted must ensure proper ventilation and disinfection activities, we aim to propose virus removal protocols for units compact enough to be installed within a van or deployed outdoor. The results confirmed the superiority (in terms of virus removal rate and time required) of the virus removal methods in the order of UV light, ventilation, and HOCl spray. Ultimately, we propose two optimal protocols: (i) UV light alone for three minutes, and (ii) UV light with ventilation for three minutes, followed by one-minute ventilation only. The time span of three minutes in the latter protocol is based on the clinical practice such that the medical staffs have a sufficient time to process the samples taken in transition to next patient to care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DisinfectionVentilationUltraviolet RaysCOVID-19Air Pollution, IndoorHumansSARS-CoV-2Air MicrobiologyHypochlorous AcidVirus Inactivation

Substanzen

Hypochlorous Acid

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Seoul National University, Seoul, Korea.
  • Department of Internal Medicine, Division of Infectious Diseases, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Institute of Advanced Machines and Design, Seoul National University, Seoul, Korea.
  • Department of Urology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.

ORCID-Profile: Young Goo Song, Hyungmin Park

Förderung

  • Korea Medical Device Development Fund
  • National Research Foundation of Korea
  • Institute of Engineering Research, Seoul National University

Zitieren

APA

Park, J., Lee, K. H., Song, Y. G., Park, H., & Lee, K. S. (2024). Development of optimal indoor air disinfection and ventilation protocols for airborne infectious diseases. PLOS ONE. https://doi.org/10.1371/journal.pone.0311274

Vancouver

Park J, Lee KH, Song YG, Park H, Lee KS. Development of optimal indoor air disinfection and ventilation protocols for airborne infectious diseases. PLOS ONE. 2024. doi:10.1371/journal.pone.0311274

BibTeX
@article{Park2024,
  author = {Park, Jooyeon and Lee, Kyoung Hwa and Song, Young Goo and Park, Hyungmin and Lee, Kwang Suk},
  title = {Development of optimal indoor air disinfection and ventilation protocols for airborne infectious diseases},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0311274}
}
Kostenlos starten →