EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudie

Intimo-intimal Intussusception during Endovascular Repair in Type B Aortic Dissection

Xiaolang Jiang, Weiguo Fu, Weifeng Lu, Shuai Ju, Bin Chen, Junhao Jiang, Daqiao Guo, Christoph A Nienaber, Zhihui Dong

European Journal of Vascular and Endovascular Surgery · 2026

DOI: 10.1016/j.ejvs.2026.02.006 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2026. Verfasst von Xiaolang Jiang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Vascular Surgery, Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; National Clinical Research Cent…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Dissection, Thoracic Aorta, Endovascular Aneurysm Repair. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Stent graft induced aortic intimo-intimal intussusception (SAoII) during thoracic endovascular aortic repair (TEVAR) of type B aortic dissection (TBAD) is a rare complication. This study aimed to report reliable imaging features of SAoII to avoid such a potentially catastrophic event. This retrospective, multicentre observational analysis was registered as a Chinese Clinical Trial (ChiCTR2300073780). METHODS: Patients undergoing TEVAR for TBAD in three centres were reviewed from January 2014 to December 2022. SAoII was defined as intra-procedural partial or circumferential disruption of the aortic intima because of TEVAR, excluding those created by natural disease progression. The imaging features and management of SAoII were summarised. RESULTS: 1 643 patients undergoing TEVAR for TBAD were reviewed. Among them, SAoII was observed in 20 patients (mean age, 44.5 ± 11.8 years; 16 men). TEVAR was performed in the acute phase (eight of 20), subacute phase (11 of 20), or chronic phase (one of 20). Imaging features including displacement of the intima, wire, or delivery system were observed in eight (40%), floating endograft in 17 (85%), intussusception of the intima layer in 13 (65%), true lumen occlusions and visceral artery loss in three (15%), and a single lumen without intimal septa in three (15%) patients. SAoII was observed in 60% (12 of 20) after deployment of the stent graft, in 20% (four of 20) after introduction of a stent graft delivery system, and in 20% (four of 20) after the introduction of a super stiff wire. All patients who developed SAoII were endovascularly managed by an additional stent graft; no aortic related death was observed among these patients with SAoII during the median follow up of 51.5 months. CONCLUSION: SAoII is a rare but potentially fatal iatrogenic complication during or after TEVAR; endovascular interventions could be effective to manage this acute complication. Timely and accurate identification of decisive imaging features are key to successful treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, ThoracicBlood Vessel Prosthesis ImplantationDissection, Thoracic AortaEndovascular Aneurysm RepairIntussusceptionAdultFemaleHumansMaleMiddle AgedBlood Vessel ProsthesisComputed Tomography AngiographyRetrospective StudiesStentsTreatment OutcomeTunica Intima

Stichwörter der Autor:innen

Iatrogenic complicationsStent graft induced aortic intimo-intimal intussusceptionThoracic endovascular aortic repairType B aortic dissection

Autor:innen und Institutionen

  • Institute of Vascular Surgery, Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; National Clinical Research Centre for Interventional Medicine, Shanghai, China.
  • Institute of Vascular Surgery, Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; National Clinical Research Centre for Interventional Medicine, Shanghai, China; Department of Vascula…
  • Department of Vascular Surgery, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen, China.
  • Centre for Vascular Surgery and Wound Care, Jinshan Hospital, Fudan University, Shanghai, China.
  • Cardiology and Aortic Centre, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London, UK.
  • Institute of Vascular Surgery, Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; National Clinical Research Centre for Interventional Medicine, Shanghai, China; Centre for Vascular S…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Jiang, X., Fu, W., Lu, W., Ju, S., Chen, B., Jiang, J., Guo, D., Nienaber, C. A., & Dong, Z. (2026). Intimo-intimal Intussusception during Endovascular Repair in Type B Aortic Dissection. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2026.02.006

Vancouver

Jiang X, Fu W, Lu W, Ju S, Chen B, Jiang J, et al. Intimo-intimal Intussusception during Endovascular Repair in Type B Aortic Dissection. European Journal of Vascular and Endovascular Surgery. 2026. doi:10.1016/j.ejvs.2026.02.006

BibTeX
@article{Jiang2026,
  author = {Jiang, Xiaolang and Fu, Weiguo and Lu, Weifeng and Ju, Shuai and Chen, Bin and Jiang, Junhao and Guo, Daqiao and Nienaber, Christoph A and Dong, Zhihui},
  title = {Intimo-intimal Intussusception during Endovascular Repair in Type B Aortic Dissection},
  journal = {European Journal of Vascular and Endovascular Surgery},
  year = {2026},
  doi = {10.1016/j.ejvs.2026.02.006}
}
Kostenlos starten →