Accuracy and Applicability of Motor Evoked Potential Monitoring during Open Thoraco-Abdominal Aortic Aneurysm Repair
European Journal of Vascular and Endovascular Surgery · 2026
DOI: 10.1016/j.ejvs.2025.12.058 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2026. Verfasst von Jelle Frankort und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, University Hospital Uniklinik Aachen, Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen, Aachen, Germany; De…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracoabdominal, Blood Vessel Prosthesis Implantation, Evoked Potentials, Motor, Intraoperative Neurophysiological Monitoring. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVE: Spinal cord ischaemia (SCI) is a devastating risk in open thoraco-abdominal aortic aneurysm (TAAA) repair, making the reliable detection and prevention of neurological injury a clinical priority. The objective of this study was to evaluate the accuracy and clinical utility of motor evoked potential (MEP) monitoring in predicting and preventing SCI during open TAAA repair. METHODS: This retrospective case series study analysed 464 patients who underwent elective TAAA repair with MEP monitoring across two academic referral centres between 2000 and 2024. All procedures were performed by the same lead surgeon with an identical neurophysiological protocol. Clinically significant MEP changes were defined as a consistent decrease in leg to arm ratio by more than 50%. Post-operative neurological outcomes were categorised as acute, delayed, or uncertain SCI. RESULTS: Clinically significant MEP changes occurred in 108 patients (23.3%), with recovery achieved in 99 cases (91.7%) following intra-operative measures to increase spinal cord perfusion. All nine patients without MEP recovery developed acute paraplegia. Among 356 patients with stable MEPs, none developed acute SCI, although 18 (5.1%) experienced delayed paraplegia associated with post-operative haemodynamic instability. The acute SCI rate was 1.9% (nine of 464), and any form of SCI (acute, delayed, or uncertain) occurred in 7.7% of cases (36 of 464). The absence of MEP signals at the end of the operation demonstrated 100% sensitivity, 100% specificity, and 100% negative and positive predictive values for acute SCI. CONCLUSION: MEP monitoring is an excellent method, providing a proper execution and a compatible anaesthetic protocol, for detecting acute peri-operative SCI and greatly influences decision making to prevent acute SCI during open TAAA procedures, although delayed SCI remains an important factor that may not be detected by MEP changes alone, largely owing to factors occurring post-operatively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular Surgery, University Hospital Uniklinik Aachen, Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen, Aachen, Germany; Department of Vascular Surgery, MUMC Maastricht, Maastricht, The Netherl…
- Department of Clinical Neurophysiology, MUMC Maastricht, Maastricht, The Netherlands.
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Medical Faculty, Ruhr University Bochum, Bochum, Germany.
- Department of Vascular Surgery, University Hospital Uniklinik Aachen, Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen, Aachen, Germany.
- Department of Vascular Surgery, MUMC Maastricht, Maastricht, The Netherlands.
Zitieren
APA
Frankort, J., Mess, W. H., Krabbe, J., Gombert, A., Mees, B. M. E., & Jacobs, M. J. (2026). Accuracy and Applicability of Motor Evoked Potential Monitoring during Open Thoraco-Abdominal Aortic Aneurysm Repair. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2025.12.058
Vancouver
Frankort J, Mess WH, Krabbe J, Gombert A, Mees BME, Jacobs MJ. Accuracy and Applicability of Motor Evoked Potential Monitoring during Open Thoraco-Abdominal Aortic Aneurysm Repair. European Journal of Vascular and Endovascular Surgery. 2026. doi:10.1016/j.ejvs.2025.12.058
BibTeX
@article{Frankort2026,
author = {Frankort, Jelle and Mess, Werner H and Krabbe, Julia and Gombert, Alexander and Mees, Barend M E and Jacobs, Michael J},
title = {Accuracy and Applicability of Motor Evoked Potential Monitoring during Open Thoraco-Abdominal Aortic Aneurysm Repair},
journal = {European Journal of Vascular and Endovascular Surgery},
year = {2026},
doi = {10.1016/j.ejvs.2025.12.058}
}
EUVIMED