Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience
European Journal of Vascular and Endovascular Surgery · 2023-07 · 66 (1) · 50-56
DOI: 10.1016/j.ejvs.2023.03.020 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2023-07. Verfasst von Ahmed Eleshra und 9 weiteren Autor:innen. Beteiligte Einrichtung: German Aortic Centre, University Heart & Vascular Centre, University Medical Centre Eppendorf, Hamburg, Germany; Department of Vascular Surgery, Facu…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Aortic Dissection, Aneurysm, False. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: British Heart Foundation.
Abstract (Originalsprache)
OBJECTIVE: To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. METHODS: A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres. RESULTS: A custom made CP was used in 155 patients (92 males, mean age 62 ± 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 - 77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 - 87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve. CONCLUSION: This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- German Aortic Centre, University Heart & Vascular Centre, University Medical Centre Eppendorf, Hamburg, Germany; Department of Vascular Surgery, Faculty of Medicine, Mansoura University, Mansoura, Egypt. Electronic addr…
- Hospital Marie Lannelongue, Paris, France.
- San Raffaele Hospital, Milan, Italy; Division of Vascular Surgery, Department of Sperimental and Clinical Sciences (DSCS), University and ASST Spedali Civili Hospital of Brescia, Brescia, Italy.
- University Health Network, Toronto, Canada.
- German Aortic Centre, University Heart & Vascular Centre, University Medical Centre Eppendorf, Hamburg, Germany.
- Skåne University Hospital, Malmö, Sweden.
Förderung
- British Heart Foundation
Zitieren
APA
Eleshra, A., Haulon, S., Bertoglio, L., Lindsay, T., Rohlffs, F., Dias, N., Tsilimparis, N., Panuccio, G., Kölbel, T., & Candy-Plug Collaborators (2023). Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience. European Journal of Vascular and Endovascular Surgery, 66(1), 50-56. https://doi.org/10.1016/j.ejvs.2023.03.020
Vancouver
Eleshra A, Haulon S, Bertoglio L, Lindsay T, Rohlffs F, Dias N, et al. Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience. European Journal of Vascular and Endovascular Surgery. 2023;66(1):50-56. doi:10.1016/j.ejvs.2023.03.020
BibTeX
@article{Eleshra2023,
author = {Eleshra, Ahmed and Haulon, Stephan and Bertoglio, Luca and Lindsay, Thomas and Rohlffs, Fiona and Dias, Nuno and Tsilimparis, Nikolaos and Panuccio, Giuseppe and Kölbel, Tilo and Candy-Plug Collaborators, Candy-Plug Collaborators},
title = {Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience},
journal = {European Journal of Vascular and Endovascular Surgery},
year = {2023},
volume = {66},
number = {1},
pages = {50--56},
doi = {10.1016/j.ejvs.2023.03.020}
}
EUVIMED