EUVIMEDEUVIMED entdecken
Crossref

Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy

Ting-Chun Kuo, Kuen-Yuan Chen, Chieh-Wen Lai, Ming-Tsan Lin, Chin-Hao Chang, Ming-Hsun Wu

European Journal of Surgical Oncology · 2024

DOI: 10.1016/j.ejso.2024.108648 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Surgical Oncology, 2024. Verfasst von Ting-Chun Kuo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan. Hauptthemen laut MEDLINE: Thyroidectomy, Parathyroid Glands, Endoscopy, Optical Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Ministry of Science and Technology, National Taiwan University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Preserving parathyroid function during thyroidectomy is crucial, but remains challenging. Real-time near-infrared autofluorescence (NIRAF) aids surgeons in intraoperative parathyroid gland (PTG) identification. However, its role in detecting PTGs unintentionally removed during surgery is unclear. STUDY DESIGN: This prospective study included adult patients undergoing endoscopic thyroidectomy. Surgeons identified and documented PTGs visually. Excised specimens underwent visual inspection and NIRAF imaging (PDE-Neo II). All fluorescent tissues were dissected and pathologically evaluated (reference standard). One scanned image per lobe was chosen to quantify autofluorescence (AF) intensity. RESULTS: Overall, 95 patients underwent endoscopic thyroidectomies, with NIRAF imaging applied to 152 excised lobes. Of these, 19 lobes displayed a total of 23 spots with increased intensity. 175 specimens were sent for pathological evaluation, and 7 were confirmed to be parathyroid tissue. NIRAF demonstrated 100.0 % sensitivity and 90.5 % specificity for predicting parathyroid tissue, with 30.4 % positive predictive value, 100.0 % negative predictive value of and 90.9 % accuracy. Quantitatively normalized, the AF signal intensity was significantly higher in NIRAF-positive tissues than negative (4.3 vs 1.2 times, p < 0.0001). Additionally, the AF signal intensity in regions pathologically confirmed of parathyroid tissue was higher than non-parathyroid tissue (9.1 vs 2.1 times, p < 0.0001). CONCLUSION: This study suggests that NIRAF has high sensitivity and specificity for detecting inadvertently resected PTGs after endoscopic thyroidectomy, contributing to preservation efforts. However, NIRAF-positive tissues still require additional confirmation through multiple methods, emphasizing other examinations to verify that they are indeed parathyroid tissues. Further research is warranted to refine NIRAF imaging parameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThyroidectomyParathyroid GlandsEndoscopyOptical ImagingHumansMaleFemaleMiddle AgedProspective StudiesAdultAgedSpectroscopy, Near-InfraredSensitivity and SpecificityThyroid Neoplasms

Stichwörter der Autor:innen

Autofluorescence (AF)Endoscopic thyroidectomyInadvertently resected parathyroid glandsNear-infrared autofluorescence (NIRAF)Parathyroid gland (PTG)

Autor:innen und Institutionen

  • Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan.
  • School of Medicine, Tzu Chi University, Hualien, Taiwan.
  • Department of Medical Research, National Taiwan University Hospital & National Taiwan University, Taipei, Taiwan.
  • Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan. Electronic address: 010028@ntuh.gov.tw.

Förderung

  • Ministry of Science and Technology
  • National Taiwan University Hospital

Zitieren

APA

Kuo, T. C., Chen, K. Y., Lai, C. W., Lin, M. T., Chang, C. H., & Wu, M. H. (2024). Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy. European Journal of Surgical Oncology. https://doi.org/10.1016/j.ejso.2024.108648

Vancouver

Kuo TC, Chen KY, Lai CW, Lin MT, Chang CH, Wu MH. Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy. European Journal of Surgical Oncology. 2024. doi:10.1016/j.ejso.2024.108648

BibTeX
@article{Kuo2024,
  author = {Kuo, Ting-Chun and Chen, Kuen-Yuan and Lai, Chieh-Wen and Lin, Ming-Tsan and Chang, Chin-Hao and Wu, Ming-Hsun},
  title = {Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy},
  journal = {European Journal of Surgical Oncology},
  year = {2024},
  doi = {10.1016/j.ejso.2024.108648}
}
Kostenlos starten →