EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Instant Intraoperative Histopathological Assessment of Fresh Parathyroid Tissue: Higher Harmonic Generation Microscopy as a Potential Alternative to Frozen Section

P M Rodriguez Schaap iD, S van den Bosch, S Spies, S van Eeden, E J M Nieveen van Dijkum, M L Groot, A F Engelsman

Head & Neck · 2025

DOI: 10.1002/hed.28146 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Head & Neck, 2025. Verfasst von P M Rodriguez Schaap und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Amsterdam University Medical Centres, Cancer Center Amsterdam, Location VUmc, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Parathyroid Glands, Microscopy, Hypoparathyroidism. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Flash Pathology, Dutch Research Council, Nederlandse Organisatie voor Wetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Hypoparathyroidism is a complication associated with significant morbidity and results from inadvertent removal of the parathyroid during thyroid surgery. Therefore, intra‐operative identification of parathyroid tissue is essential to minimize the risk of hypoparathyroidism. Current identification techniques come with significant limitations in logistics and accuracy. We therefore propose higher‐harmonic generation microscopy (HHGM), a rapid, non‐invasive, label‐free method for the real‐time visualization of human tissue, as a potential alternative.

Methods

A prospective proof‐of‐concept study was conducted at the Amsterdam University Medical Centers from February to April 2024. Intra‐operative HHGM imaging of presumed parathyroid tissue samples was performed, and the results were compared with conventional histopathology by an expert endocrine pathologist in order to evaluate the sensitivity and specificity of HHGM. The logistical process and its potentially associated benefits were also evaluated.

Results

Intraoperative imaging was performed on 32 fresh, unprocessed tissue samples from 18 patients. HHGM demonstrated a high sensitivity (85%) and specificity (83.3%) for the detection of parathyroid tissue. HHGM imaging was found to be more time‐efficient than frozen section, taking ~5 min per biopsy compared to 30 min for FS. HHGM was able to produce high‐quality images in cases where frozen section analysis was inconclusive due to insufficient tissue. Logistical challenges and extra workload associated with HHGM were minimal.

Conclusion

This proof‐of‐concept study demonstrates that HHGM could be a promising intraoperative diagnostic imaging modality, offering rapid imaging and detailed visualization capabilities. These features suggest that HHGM might potentially reduce surgery duration and decrease demand on pathology resources.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Parathyroid GlandsMicroscopyHypoparathyroidismHumansProspective StudiesFrozen SectionsMaleFemaleMiddle AgedSensitivity and SpecificityAdultAgedProof of Concept StudyThyroidectomyParathyroidectomy

Stichwörter der Autor:innen

frozen sectionhigher‐harmonic generation microscopy (HHGM)hypoparathyroidismintraoperative diagnosticparathyroidthyroidectomy

Autor:innen und Institutionen

  • Department of Surgery, Amsterdam University Medical Centres, Cancer Center Amsterdam, Location VUmc, Amsterdam, the Netherlands.
  • Laserlab Amsterdam, Department of Physics, Faculty of Science, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
  • Department of Pathology, Amsterdam University Medical Centres, Location VUmc, Amsterdam, the Netherlands.

ORCID-Profile: P M Rodriguez Schaap

Förderung

  • Flash Pathology
  • Dutch Research Council
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Zitieren

APA

Schaap, P. M. R., van den Bosch, S., Spies, S., van Eeden, S., van Dijkum, E. J. M. N., Groot, M. L., & Engelsman, A. F. (2025). Instant Intraoperative Histopathological Assessment of Fresh Parathyroid Tissue: Higher Harmonic Generation Microscopy as a Potential Alternative to Frozen Section. Head & Neck. https://doi.org/10.1002/hed.28146

Vancouver

Schaap PMR, van den Bosch S, Spies S, van Eeden S, van Dijkum EJMN, Groot ML, et al. Instant Intraoperative Histopathological Assessment of Fresh Parathyroid Tissue: Higher Harmonic Generation Microscopy as a Potential Alternative to Frozen Section. Head & Neck. 2025. doi:10.1002/hed.28146

BibTeX
@article{Schaap2025,
  author = {Schaap, P M Rodriguez and van den Bosch, S and Spies, S and van Eeden, S and van Dijkum, E J M Nieveen and Groot, M L and Engelsman, A F},
  title = {Instant Intraoperative Histopathological Assessment of Fresh Parathyroid Tissue: Higher Harmonic Generation Microscopy as a Potential Alternative to Frozen Section},
  journal = {Head & Neck},
  year = {2025},
  doi = {10.1002/hed.28146}
}
Kostenlos starten →