EUVIMEDEUVIMED entdecken
Validierungsstudie

Transvaginal ultrasound for deep endometriosis: Prospective validation of SRU criteria and diagnostic value of indirect signs

Yixuan Hu, Jinxia Wang, Lingzhi Meng, Jinzhen Song, Zongli Yang

European Journal of Radiology · 2026

DOI: 10.1016/j.ejrad.2026.112702 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Yixuan Hu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Abdominal Ultrasound, Affiliated Hospital of Qingdao University, Qingdao, China. Hauptthemen laut MEDLINE: Endometriosis. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The SRU consensus on pelvic ultrasound proposed standardized augmented ultrasound, but its validity and indirect signs' role require validation. This study will explore the application value of this consensus in deep endometriosis. METHOD: This prospective study enrolled patients with clinically suspected endometriosis at Qingdao University Affiliated Hospital from May 2024 to April 2025. TVUS findings were compared with surgical findings. The diagnostic performance of TVUS for endometriosis was calculated, and multivariable logistic regression was applied to analyze associations between indirect sonographic signs and lesion locations. RESULTS: Included were 288 patients with clinical suspicion of DE. For DE detection, TVUS showed an overall accuracy of 84.4% (sensitivity 87.4%, specificity 76.8%). Fixed uterine retroflexion was significantly associated with bowel (OR 2.07, 95% CI 1.16-3.71), RVS (OR 2.83, 95% CI 1.34-6.32), and uterine serosal involvement (OR 2.38, 95% CI 1.19-4.88). Bowel tethering predicted bowel (OR 6.45, 95% CI 3.69-11.53), RVS (OR 4.53, 95% CI 2.24-9.62), uterine serosal (OR 2.15, 95% CI 1.12-4.18), and vaginal lesions (OR 3.83, 95% CI 1.85-8.25). Ipsilateral ovarian fixation or abnormal position was indicative of ipsilateral ovarian endometriosis (right: OR 16.9, 95% CI 9.15-32.96; left: OR 14.54, 95% CI 8.02-27.63) and USL involvement (right: OR 4.38, 95% CI 2.40-8.29, left: OR 2.23, 95%CI 1.3-3.91). CONCLUSION: SRU-based ultrasound demonstrates high diagnostic accuracy for DE. Indirect signs effectively localize endometriotic lesions, enhancing surgical planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EndometriosisHumansFemaleProspective StudiesUltrasonographySensitivity and SpecificityAdultReproducibility of ResultsVagina

Stichwörter der Autor:innen

Deep endometriosisIndirect signsTransvaginal ultrasound

Autor:innen und Institutionen

  • Department of Abdominal Ultrasound, Affiliated Hospital of Qingdao University, Qingdao, China.
  • Department of Ultrasound, Gaomi People's Hospital, Weifang, China.
  • Obstetrics and Gynecology Ultrasound Department, Qingdao Women and Children's Hospital, Qingdao, China.
  • Department of Abdominal Ultrasound, Affiliated Hospital of Qingdao University, Qingdao, China. Electronic address: qingyichaosheng@126.com.

Förderung

  • Natural Science Foundation of Shandong Province

Zitieren

APA

Hu, Y., Wang, J., Meng, L., Song, J., & Yang, Z. (2026). Transvaginal ultrasound for deep endometriosis: Prospective validation of SRU criteria and diagnostic value of indirect signs. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2026.112702

Vancouver

Hu Y, Wang J, Meng L, Song J, Yang Z. Transvaginal ultrasound for deep endometriosis: Prospective validation of SRU criteria and diagnostic value of indirect signs. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2026.112702

BibTeX
@article{Hu2026,
  author = {Hu, Yixuan and Wang, Jinxia and Meng, Lingzhi and Song, Jinzhen and Yang, Zongli},
  title = {Transvaginal ultrasound for deep endometriosis: Prospective validation of SRU criteria and diagnostic value of indirect signs},
  journal = {European Journal of Radiology},
  year = {2026},
  doi = {10.1016/j.ejrad.2026.112702}
}
Kostenlos starten →