EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC-ND 4.0

Accuracy of ultrasound signs on two‐dimensional transvaginal ultrasound in prediction of adenomyosis: prospective multicenter study

H Krentel iD, J Keckstein iD, T Füger, D Hornung, J Theben, D Salehin, O Buchweitz, A Mueller, S D Schäfer iD, M Sillem, K W Schweppe, G Tchartchian und 2 weitere

Ultrasound in Obstetrics & Gynecology · 2023-11 · 62 (5) · 739-746

DOI: 10.1002/uog.26197 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Ultrasound in Obstetrics & Gynecology, 2023-11. Verfasst von H Krentel und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gynecology, Obstetrics and Gynecological Oncology, Academic Teaching Hospital, Bethesda Krankenhaus Duisburg, Duisburg, Germany. Hauptthemen laut MEDLINE: Cysts, Adenomyosis, Endometriosis. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Two‐dimensional (2D) transvaginal ultrasound (TVS) is an accessible and cost‐effective diagnostic tool for the detection of adenomyosis. Different ultrasound features related to adenomyosis have been described, but the predictive value of each ultrasound sign and their combinations requires further investigation. We aimed to analyze the accuracy of 2D‐TVS and describe possible combinations of ultrasound signs with a high predictive value in the diagnosis of adenomyosis.

Methods

This was a prospective multicenter study of patients scheduled for laparoscopic hysterectomy who had been examined using standardized 2D‐TVS at nine expert centers specializing in the diagnosis and treatment of endometriosis. 2D‐TVS examination included nine typical adenomyosis ultrasound features, comprising heterogeneous myometrium, myometrial linear striations, myometrial cysts, subendometrial microcysts, asymmetrical myometrial thickening, uterine enlargement, the ‘question mark sign’, thickening of the junctional zone and hyperechoic myometrial spots, in order to predict or exclude the presence of adenomyosis. Ultrasound examination results were compared with histology after hysterectomy. The diagnostic reliability of the nine ultrasound signs and their combinations, and the influence of concurrent fibroids on the accuracy of the results, were analyzed.

Results

A total of 202 patients were enrolled into the study. Histopathological examination revealed adenomyosis in 130 patients (64.4%). The accuracy of prediction of adenomyosis by 2D‐TVS examination using all signs was 63.4% (positive predictive value, 71.5%; negative predictive value, 48.6%; sensitivity, 71.5%; specificity, 48.6%). Heterogeneous myometrium, myometrial cysts, subendometrial microcysts and hyperechoic myometrial spots showed the highest accuracy (55.7–62.1%) as individual ultrasound signs for the prediction of adenomyosis. The combination of the most accurate ultrasound signs (subendometrial microcysts, myometrial cysts and heterogeneous myometrium) improved the specificity of prediction (86.1%) when compared with that of these three single markers (35.2–81.7%). Uterine enlargement and asymmetry showed both low sensitivity (60.8% and 52.3%, respectively) and specificity (41.7% and 49.3%, respectively) as individual sonographic signs.

Conclusions

Heterogeneous myometrium, myometrial cysts, subendometrial microcysts and hyperechoic myometrial spots showed the highest accuracy for the detection of adenomyosis in this study, while uterine enlargement and asymmetry led to high false‐positive and false‐negative results. A combination of ultrasound features including the most accurate signs increases specificity. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CystsAdenomyosisEndometriosisUterusSensitivity and SpecificityMyometriumReproducibility of ResultsFemaleProspective StudiesHumansUrogenital AbnormalitiesUltrasonography

Stichwörter der Autor:innen

adenomyosisasymmetrydysmenorrhealinear striationmyometrial cystquestion mark signsubendometrial cysttransvaginal ultrasound

Autor:innen und Institutionen

  • Department of Gynecology, Obstetrics and Gynecological Oncology, Academic Teaching Hospital, Bethesda Krankenhaus Duisburg, Duisburg, Germany.
  • Endometriosis Clinic, Dres. Keckstein, Villach, Austria.
  • MIC Zentrum, München, Germany.
  • Department of Obstetrics and Gynecology, Vidia Diakonissenkrankenhaus, Karlsruhe, Germany.
  • Department of Obstetrics and Gynecology, St Elisabeth Hospital Köln-Hohenlind, Köln, Germany.
  • Department of Obstetrics and Gynecology, Evangelisches Krankenhaus Bethesda, Mönchengladbach, Germany.

ORCID-Profile: H Krentel, J Keckstein, S D Schäfer

Zitieren

APA

Krentel, H., Keckstein, J., Füger, T., Hornung, D., Theben, J., Salehin, D., Buchweitz, O., Mueller, A., Schäfer, S. D., Sillem, M., Schweppe, K. W., Tchartchian, G., Gilman, E., & De Wilde, R. L. (2023). Accuracy of ultrasound signs on two‐dimensional transvaginal ultrasound in prediction of adenomyosis: prospective multicenter study. Ultrasound in Obstetrics & Gynecology, 62(5), 739-746. https://doi.org/10.1002/uog.26197

Vancouver

Krentel H, Keckstein J, Füger T, Hornung D, Theben J, Salehin D, et al. Accuracy of ultrasound signs on two‐dimensional transvaginal ultrasound in prediction of adenomyosis: prospective multicenter study. Ultrasound in Obstetrics & Gynecology. 2023;62(5):739-746. doi:10.1002/uog.26197

BibTeX
@article{Krentel2023,
  author = {Krentel, H and Keckstein, J and Füger, T and Hornung, D and Theben, J and Salehin, D and Buchweitz, O and Mueller, A and Schäfer, S D and Sillem, M and Schweppe, K W and Tchartchian, G and Gilman, E and De Wilde, R L},
  title = {Accuracy of ultrasound signs on two‐dimensional transvaginal ultrasound in prediction of adenomyosis: prospective multicenter study},
  journal = {Ultrasound in Obstetrics & Gynecology},
  year = {2023},
  volume = {62},
  number = {5},
  pages = {739--746},
  doi = {10.1002/uog.26197}
}
Kostenlos starten →