Diagnostic Value of Dual‐Energy CT Iodine Mapping in Differentiating Malignant and Benign Cervical Lymphadenopathies
Journal of Clinical Ultrasound · 2025
DOI: 10.1002/jcu.24014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Mustafa Başaran und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Faculty of Medicine, Samsun University, Samsun, Turkey. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Dual-Energy Scanned Projection, Iodine, Head and Neck Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the diagnostic accuracy of Dual‐Energy Computed Tomography (DECT) in distinguishing malignant from benign cervical lymph nodes in neck carcinoma based on iodine concentration and normalized spectral attenuation (Hounsfield Unit, HU) values.
Methods
Retrospective DECT scan analysis was performed on 52 neck carcinoma patients, analyzing 52 metastatic and 28 reactive lymph nodes. Iodine concentration (mg/mL) and spectral HU values were measured with circular regions of interest on iodine maps. Metastatic nodes included 27 from squamous cell carcinoma (SCC), 19 from lymphoma, and 6 from papillary thyroid carcinoma (PTC).
Results
Metastatic lymph nodes had lower iodine levels than reactive nodes (1.45 vs. 1.85 mg/mL, p = 0.011). No significant difference in spectral HU values was found (117 vs. 111 HU, p = 0.328). An iodine threshold of 1.62 mg/mL demonstrated 71% sensitivity and 77% specificity for detecting malignancy (AUC = 0.673, 95% CI: 0.54–0.80, p = 0.011). SCC metastases had lower iodine levels than reactive nodes (1.33 vs. 1.85 mg/mL, p < 0.001), while PTC metastases had higher levels (2.39 vs. 1.85 mg/mL, p = 0.038).
Conclusion
DECT iodine quantification improves the detection of cervical lymph node metastases, particularly in cases with equivocal size criteria. Incorporating iodine measurements with tumor type knowledge improves diagnostic accuracy, aiding in prognosis and treatment planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Faculty of Medicine, Samsun University, Samsun, Turkey.
- Department of Radiology, Faculty of Medicine, Recep Tayyip Erdoğan University, Rize, Turkey.
- Department of Otorhinolaryngology, Faculty of Medicine, Recep Tayyip Erdoğan University, Rize, Turkey.
- Department of Radiology, Ministry of Health Karakoçan State Hospital, Elazığ, Turkey.
ORCID-Profile: Mustafa Başaran, Fatma Beyazal Çeliker, Metin Çeliker, Kemal Panç, Enes Gürün
Zitieren
APA
Başaran, M., Çeliker, F. B., Çeliker, M., Panç, K., & Gürün, E. (2025). Diagnostic Value of Dual‐Energy CT Iodine Mapping in Differentiating Malignant and Benign Cervical Lymphadenopathies. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.24014
Vancouver
Başaran M, Çeliker FB, Çeliker M, Panç K, Gürün E. Diagnostic Value of Dual‐Energy CT Iodine Mapping in Differentiating Malignant and Benign Cervical Lymphadenopathies. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.24014
BibTeX
@article{Baaran2025,
author = {Başaran, Mustafa and Çeliker, Fatma Beyazal and Çeliker, Metin and Panç, Kemal and Gürün, Enes},
title = {Diagnostic Value of Dual‐Energy CT Iodine Mapping in Differentiating Malignant and Benign Cervical Lymphadenopathies},
journal = {Journal of Clinical Ultrasound},
year = {2025},
doi = {10.1002/jcu.24014}
}
EUVIMED