EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Diagnostic accuracy of the STOP-Bang questionnaire for obstructive sleep apnea in pregnancy: A systematic review and meta-analysis

Abdulrhman H M Muhaisen, Ayham Assaf, Mohammad Aleidi, Faris Al-Rabba, Mohammad Al-Nayef, Ibrahim Al-Natsheh, Mahdi Qasaymeh

European Journal of Obstetrics & Gynecology and Reproductive Biology · 2026

DOI: 10.1016/j.ejogrb.2026.115083 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift European Journal of Obstetrics & Gynecology and Reproductive Biology, 2026. Verfasst von Abdulrhman H M Muhaisen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Yarmouk University, Irbid, Jordan. Electronic address: Muhaisen.dopamine@gmail.com. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Pregnancy Complications. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Obstructive sleep apnea (OSA) in pregnancy is associated with adverse maternal and perinatal outcomes, yet timely diagnostic testing can be limited. Screening questionnaires such as STOP-Bang are therefore used to triage patients for objective testing. OBJECTIVE: To synthesize evidence on the diagnostic accuracy of the STOP-Bang questionnaire for detecting OSA in pregnancy. METHODS: We conducted a PRISMA 2020-compliant systematic review (PROSPERO: CRD420261297348). PubMed, Scopus, Web of Science, and EBSCOhost databases were searched from inception through February 2026. Eligible studies evaluated STOP-Bang in pregnant participants against polysomnography (PSG) or home sleep apnea testing (HSAT)/portable monitoring. The risk of bias was assessed using the QUADAS-2. When ≥ 2 studies provided complete (or derivable) 2 × 2 data at STOP-Bang ≥ 3 and AHI/REI ≥ 5, we performed a hierarchical bivariate random-effects diagnostic meta-analysis (Reitsma model; REML) to pool sensitivity and specificity jointly; pathway-based partial verification studies were synthesized narratively. RESULTS: Five cohort studies (2015-2024) comprising 1,096 pregnant participants were included; 573 underwent objective sleep testing. Reference standards were predominantly HSAT/portable monitoring, with limited PSG in a small subset in one study. Reported diagnostic performance varied across studies, with sensitivity ranging from approximately 0.53 to 0.63 and specificity from 0.36 to 0.90 [1-3], and individual-study AUC values ranging from approximately 0.63 to 0.75. Studies embedded within referral pathways or with partial verification yielded less stable and potentially biased estimates. QUADAS-2 identified flow and timing as the most frequent concern due to partial verification/work-up bias. Hierarchical meta-analysis (STOP-Bang ≥ 3; AHI/REI ≥ 5) yielded pooled sensitivity 0.587 (95% CI 0.464-0.699) and pooled specificity 0.749 (95% CI 0.360-0.941), with AUC 0.604. In sensitivity analysis excluding a class III obesity cohort, pooled specificity increased to 0.860 and AUC to 0.832, while pooled sensitivity remained similar (0.566). Sensitivity was relatively consistent across studies, whereas specificity varied widely. CONCLUSION: Current evidence does not support STOP-Bang as a reliable stand-alone screening tool for obstructive sleep apnea in pregnancy. Its diagnostic performance appears variable and generally modest, and pregnant patients with suspected OSA should undergo objective sleep evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sleep Apnea, ObstructivePregnancy ComplicationsHumansFemalePregnancySurveys and QuestionnairesPolysomnographySensitivity and Specificity

Stichwörter der Autor:innen

Home sleep apnea testingObstructive sleep apneaPolysomnographyPregnancySTOP-BangSleep-disordered breathing

Autor:innen und Institutionen

  • Faculty of Medicine, Yarmouk University, Irbid, Jordan. Electronic address: Muhaisen.dopamine@gmail.com.
  • Faculty of Medicine, Yarmouk University, Irbid, Jordan.

Zitieren

APA

Muhaisen, A. H. M., Assaf, A., Aleidi, M., Al-Rabba, F., Al-Nayef, M., Al-Natsheh, I., & Qasaymeh, M. (2026). Diagnostic accuracy of the STOP-Bang questionnaire for obstructive sleep apnea in pregnancy: A systematic review and meta-analysis. European Journal of Obstetrics & Gynecology and Reproductive Biology. https://doi.org/10.1016/j.ejogrb.2026.115083

Vancouver

Muhaisen AHM, Assaf A, Aleidi M, Al-Rabba F, Al-Nayef M, Al-Natsheh I, et al. Diagnostic accuracy of the STOP-Bang questionnaire for obstructive sleep apnea in pregnancy: A systematic review and meta-analysis. European Journal of Obstetrics & Gynecology and Reproductive Biology. 2026. doi:10.1016/j.ejogrb.2026.115083

BibTeX
@article{Muhaisen2026,
  author = {Muhaisen, Abdulrhman H M and Assaf, Ayham and Aleidi, Mohammad and Al-Rabba, Faris and Al-Nayef, Mohammad and Al-Natsheh, Ibrahim and Qasaymeh, Mahdi},
  title = {Diagnostic accuracy of the STOP-Bang questionnaire for obstructive sleep apnea in pregnancy: A systematic review and meta-analysis},
  journal = {European Journal of Obstetrics & Gynecology and Reproductive Biology},
  year = {2026},
  doi = {10.1016/j.ejogrb.2026.115083}
}
Kostenlos starten →