Diagnostic Performance of a Type III Portable Monitoring Device for Obstructive Sleep Apnea in Pregnant Women: A Prospective Validation Study
Journal of Women's Health · 01.05.2025 · 34 (5) · 685-693
DOI: 10.1089/jwh.2024.1033 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Women's Health, erschienen am 01.05.2025. Verfasst von Sofía Romero-Peralta und 10 weiteren Autor:innen. Beteiligte Einrichtung: Sleep Unit, Pneumology Department, Hospital Universitario de Guadalajara, Guadalajara, Spain. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Polysomnography, Pregnancy Complications, Monitoring, Ambulatory. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Rationale
Obstructive sleep apnea (OSA) during pregnancy is linked to negative maternal and neonatal outcomes. Diagnosing OSA in this population is particularly challenging. Portable monitoring devices (PMD) present a potential alternative to polysomnography (PSG), but their effectiveness in pregnant women is uncertain.
Objective
To evaluate diagnostic accuracy of a PMD to detect OSA in pregnant women.
Methods
A prospective study of 136 middle-aged pregnant women (34 ± 4 years) in their third trimester of pregnancy (34 ± 3 weeks) who underwent laboratory type III PMD and PSG simultaneously.
Results
Using an apnea-hypopnea index (AHI) ≥5 event/h by PSG, OSA was diagnosed in 10.3% of women (mild OSA: 86%; moderate OSA: 14%). An acceptable positive correlation was found between both tests in the AHI (r = 0.787; p < 0.001) and oxygen desaturation index (ODI) (r = 0.806; p < 0.001). The agreement limits between PSG and type III PMD were -4.1 to 5.4 for AHI and -6.0 to 4.5 for ODI. The sensitivity and specificity of type III PMD for an AHI ≥5 events/h were 57.1% and 99.2%, respectively, with a positive predictive value (PPV) of 88.9% and a negative predictive value (NPV) of 95.3%. On a receiver operating characteristic curve, the best cutoff point of AHI by type III PMD to identify OSA according to PSG criteria was 2.25 events/h. The sensibility and specificity for this point were 85.7% and 88.5%, respectively, with a PPV of 46.2% and NPV of 98.2%.
Conclusions
A type III PMD with an AHI cutoff of 5 events/h could be a good alternative for OSA diagnosis in pregnant women. Additionally, an AHI ≥2.25 event/h demonstrates good diagnostic performance, but its low positive predictive value suggests that it is more appropriate as a screening tool. Further studies are needed to validate this sleep study tool in pregnant women, particularly in home settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sleep Unit, Pneumology Department, Hospital Universitario de Guadalajara, Guadalajara, Spain.
- Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), Madrid, Spain.
- Instituto de Investigación Sanitaria Castilla La Mancha (IDISCAM), Toledo, Spain.
- Medicine Department, Universidad de Alcalá, Madrid, Spain.
- Department of Pneumology, Hospital de Manacor, Palma de Mallorca, Spain.
- Sleep Unit, Hospital Universitario de Araba, Vitoria, Spain.
Zitieren
APA
Romero-Peralta, S., Alonso, M., Mediano, O., Moncadas, M. C., Álvarez Ruiz De Larrinaga, A., Codina Marcet, M., Giménez Carrero, M. P., de la Peña, M., Peña Zarza, J. A., García-Río, F., & Alonso-Fernández, A. (2025). Diagnostic Performance of a Type III Portable Monitoring Device for Obstructive Sleep Apnea in Pregnant Women: A Prospective Validation Study. Journal of Women's Health, 34(5), 685-693. https://doi.org/10.1089/jwh.2024.1033
Vancouver
Romero-Peralta S, Alonso M, Mediano O, Moncadas MC, Álvarez Ruiz De Larrinaga A, Codina Marcet M, et al. Diagnostic Performance of a Type III Portable Monitoring Device for Obstructive Sleep Apnea in Pregnant Women: A Prospective Validation Study. Journal of Women's Health. 2025;34(5):685-693. doi:10.1089/jwh.2024.1033
BibTeX
@article{RomeroPeralta2025,
author = {Romero-Peralta, Sofía and Alonso, Miguel and Mediano, Olga and Moncadas, María Cerdà and Álvarez Ruiz De Larrinaga, Ainhoa and Codina Marcet, Mercedes and Giménez Carrero, María Paloma and de la Peña, Mónica and Peña Zarza, José Antonio and García-Río, Francisco and Alonso-Fernández, Alberto},
title = {Diagnostic Performance of a Type III Portable Monitoring Device for Obstructive Sleep Apnea in Pregnant Women: A Prospective Validation Study},
journal = {Journal of Women's Health},
year = {2025},
volume = {34},
number = {5},
pages = {685--693},
doi = {10.1089/jwh.2024.1033}
}
EUVIMED