Validation and optimization of dual-energy CT for accurate dose calculation in photon radiotherapy of brain metastases
Physica Medica · 2026
DOI: 10.1016/j.ejmp.2025.105702 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Physica Medica, 2026. Verfasst von Gary Razinskas und 6 weiteren Autor:innen. Beteiligte Einrichtung: University Hospital Würzburg, Department of Radiotherapy and Radiation Oncology, Josef-Schneider-Str. 11, 97080 Würzburg, Germany. Electronic address…. Hauptthemen laut MEDLINE: Brain Neoplasms, Photons, Radiotherapy Planning, Computer-Assisted, Tomography, X-Ray Computed. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
PURPOSE: Dual-energy computed tomography (DECT) offers enhanced tissue contrast and the potential for direct electron density mapping, but its role in accurate dose calculation for radiotherapy remains underexplored. This study evaluates whether DECT-derived reconstructions can reproduce conventional single-energy CT (SECT)-based dose distributions for stereotactic brain radiotherapy while minimizing workflow disruption. METHODS: A Gammex Advanced Electron Density Phantom (Sun Nuclear, Melbourne, FL, USA) was scanned using a twin-spiral DECT protocol on a Somatom go.Open Pro CT scanner (Siemens Healthineers, Forchheim, Germany). Calibration curves were derived for virtual monoenergetic images (VMI) across 40-190 keV and for direct electron density (Rho) reconstructions. An optimal VMI energy (VMIopt) was identified to match the SECT calibration. Retrospective dose calculations were performed on 24 stereotactic treatment plans for brain metastases, comparing standard SECT, VMIopt, and Rho datasets. Dose-volume histogram (DVH) metrics and gamma analyses assessed accuracy. RESULTS: An optimal VMI energy of 72 keV closely replicated the standard SECT calibration. VMIopt-based dose calculations showed minimal dosimetric deviations, with mean differences of 0.27%, 0.37%, and 0.41% for D95%, D98%, and D99%, respectively. Rho-based reconstructions exhibited slightly larger variations, averaging 0.75%, 0.92%, and 1.02% for the same parameters. Gamma analysis demonstrated pass rates above 99.6% for VMIopt and above 99.1% for Rho using 1%/1 mm criteria, even in high-dose and steep-gradient regions. CONCLUSION: Both 72 keV VMI and Rho-based DECT reconstructions enable accurate, clinically acceptable dose calculations for stereotactic radiotherapy of brain metastases. These findings support DECT's integration into clinical workflows, enhancing planning precision without increasing operational complexity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University Hospital Würzburg, Department of Radiotherapy and Radiation Oncology, Josef-Schneider-Str. 11, 97080 Würzburg, Germany. Electronic address: Razinskas_G@ukw.de.
- University Hospital Würzburg, Department of Radiotherapy and Radiation Oncology, Josef-Schneider-Str. 11, 97080 Würzburg, Germany.
Zitieren
APA
Razinskas, G., Jegelka, C., Weick, S., Kraft, J., Lutyj, P., Wittig-Sauerwein, A., & Richter, A. (2026). Validation and optimization of dual-energy CT for accurate dose calculation in photon radiotherapy of brain metastases. Physica Medica. https://doi.org/10.1016/j.ejmp.2025.105702
Vancouver
Razinskas G, Jegelka C, Weick S, Kraft J, Lutyj P, Wittig-Sauerwein A, et al. Validation and optimization of dual-energy CT for accurate dose calculation in photon radiotherapy of brain metastases. Physica Medica. 2026. doi:10.1016/j.ejmp.2025.105702
BibTeX
@article{Razinskas2026,
author = {Razinskas, Gary and Jegelka, Chiara and Weick, Stefan and Kraft, Johannes and Lutyj, Paul and Wittig-Sauerwein, Andrea and Richter, Anne},
title = {Validation and optimization of dual-energy CT for accurate dose calculation in photon radiotherapy of brain metastases},
journal = {Physica Medica},
year = {2026},
doi = {10.1016/j.ejmp.2025.105702}
}
EUVIMED