The BeamSplitter – An algorithm providing the dose per control point of radiation therapy treatment plans
Physica Medica · 2024-12 · 128 · 104845
DOI: 10.1016/j.ejmp.2024.104845 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2024-12. Verfasst von Mathieu Gaudreault und 3 weiteren Autor:innen. Beteiligte Einrichtung: Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria…. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Algorithms, Radiotherapy Dosage. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Cancer Council Victoria, Peter MacCallum Cancer Centre, University of Wollongong.
Abstract (Originalsprache)
PURPOSE: Commercial radiation therapy treatment planning systems (TPS) provide the three-dimensional time-integrated planned dose distribution. A four-dimensional (4D) dose calculation is essential to minimise dose-rate effects on pacemaker or in total body irradiation treatment or for time-dependent patient-specific quality assurance. We introduce the BeamSplitter, an algorithm in a commercial TPS generating 4D dose calculation. METHODS: Automation was performed with the Eclipse Scripting Application Programming Interface (ESAPI, v16, Varian Medical System). The accumulated and reference dose distributions of twenty-one patients treated in 2022 at our institution were compared. The patients were selected to cover a broad range of modulated delivery techniques and plan complexity, quantified with the average leaf pair opening (ALPO). The dose distributions were compared with gamma passing rates (γPR). Moreover, the mean absolute percentage error (MAPE) between accumulated and reference dose metrics (planning target volume (PTV) D99% / D95% in stereotactic / non-stereotactic treatment, organs at risk (OAR) D5cc / D0.03 cc, and mean dose) was calculated. Dose accumulation was validated by point dose measurement. RESULTS: The ALPO ranged from 11.6 mm to 77 mm. The accumulated and reference dose distributions were similar (γPR0mm1% > 90 % in all patients). The MAPE between reference and accumulated dose metrics was lower than 1 % in all cases. The average dose difference through time between the accumulated and measured dose was lower than our clinical tolerance of 3 %. CONCLUSIONS: The BeamSplitter is the first validated algorithm generating a 4D dose calculation of radiation therapy treatment plans within a commercial TPS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia. Electronic address: mathieu.gaudreault@petermac.org.
- Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia; Australian Radiation Protection and Nuclear Safety A…
- Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia; Central Clinical School, Monash University, Melbourn…
- Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia; Centre for Medical Radiation Physics, University of…
Förderung
- Cancer Council Victoria
- Peter MacCallum Cancer Centre
- University of Wollongong
- Peter MacCallum Cancer Foundation Ltd
Zitieren
APA
Gaudreault, M., Burton, A., Panettieri, V., & Hardcastle, N. (2024). The BeamSplitter – An algorithm providing the dose per control point of radiation therapy treatment plans. Physica Medica, 128, 104845. https://doi.org/10.1016/j.ejmp.2024.104845
Vancouver
Gaudreault M, Burton A, Panettieri V, Hardcastle N. The BeamSplitter – An algorithm providing the dose per control point of radiation therapy treatment plans. Physica Medica. 2024;128:104845. doi:10.1016/j.ejmp.2024.104845
BibTeX
@article{Gaudreault2024,
author = {Gaudreault, Mathieu and Burton, Alex and Panettieri, Vanessa and Hardcastle, Nicholas},
title = {The BeamSplitter – An algorithm providing the dose per control point of radiation therapy treatment plans},
journal = {Physica Medica},
year = {2024},
volume = {128},
pages = {104845},
doi = {10.1016/j.ejmp.2024.104845}
}
EUVIMED