First clinical experience following the consensus guide for calibrating a proton stopping power ratio curve in a new proton centre
Physica Medica · 2024
DOI: 10.1016/j.ejmp.2024.103341 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2024. Verfasst von Calvin Wei Yang Koh und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiation Oncology, National Cancer Centre Singapore, Singapore. Hauptthemen laut MEDLINE: Proton Therapy, Protons. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: This work introduces the first assessment of CT calibration following the ESTRO's consensus guidelines and validating the HLUT through the irradiation of biological material. METHODS: Two electron density phantoms were scanned with two CT scanners using two CT scan energies. The stopping power ratio (SPR) and mass density (MD) HLUTs for different CT scan energies were derived using Schneider's and ESTRO's methods. The comparison metric in this work is based on the Water-Equivalent Thickness (WET) difference between the treatment planning system and biological irradiation measurement. The SPR HLUTs were compared between the two calibration methods. To assess the accuracy of using MD HLUT for dose calculation in the treatment planning system, MD vs SPR HLUT was compared. Lastly, the feasibility of using a single SPR HLUT to replace two different energy CT scans was explored. RESULTS: The results show a WET difference of less than 3.5% except for the result in the Bone region between Schneider's and ESTRO's methods. Comparing MD and SPR HLUT, the results from MD HLUT show less than a 3.5% difference except for the Bone region. However, the SPR HLUT shows a lower mean absolute percentage difference as compared to MD HLUT between the measured and calculated WET difference. Lastly, it is possible to use a single SPR HLUT for two different CT scan energies since both WET differences are within 3.5%. CONCLUSION: This is the first report on calibrating an HLUT following the ESTRO's guidelines. While our result shows incremental improvement in range uncertainty using the ESTRO's guideline, the prescriptional approach of the guideline does promote harmonization of CT calibration protocols between different centres.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore.
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Nanyang Technological University Singapore, Singapore.
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Department of Oncology, University of Cambridge, United Kingdom.
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore. Electronic address: hqtan1988@gmail.com.
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore.
Zitieren
APA
Koh, C. W. Y., Lew, K. S., Wibawa, A., Master, Z., Yeap, P. L., Chua, C. G. A., Lee, J. C. L., Tan, H. Q., & Park, S. Y. (2024). First clinical experience following the consensus guide for calibrating a proton stopping power ratio curve in a new proton centre. Physica Medica. https://doi.org/10.1016/j.ejmp.2024.103341
Vancouver
Koh CWY, Lew KS, Wibawa A, Master Z, Yeap PL, Chua CGA, et al. First clinical experience following the consensus guide for calibrating a proton stopping power ratio curve in a new proton centre. Physica Medica. 2024. doi:10.1016/j.ejmp.2024.103341
BibTeX
@article{Koh2024,
author = {Koh, Calvin Wei Yang and Lew, Kah Seng and Wibawa, Andrew and Master, Zubin and Yeap, Ping Lin and Chua, Clifford Ghee Ann and Lee, James Cheow Lei and Tan, Hong Qi and Park, Sung Yong},
title = {First clinical experience following the consensus guide for calibrating a proton stopping power ratio curve in a new proton centre},
journal = {Physica Medica},
year = {2024},
doi = {10.1016/j.ejmp.2024.103341}
}
EUVIMED