EUVIMEDEUVIMED entdecken
Vergleichsstudie

A retrospective analysis of factors associated with deep contraceptive implant removals compared to superficial removals

Paige D Kendall, Wyanet Bresnitz, Jin Huang, Jeanelle Sheeder, Aaron Lazorwitz

Contraception · 2024

DOI: 10.1016/j.contraception.2024.110486 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Contraception, 2024. Verfasst von Paige D Kendall und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Division of Family Planning, University of Colorado Anschutz Medical Campus, Aurora, CO, United States. Elec…. Hauptthemen laut MEDLINE: Device Removal, Desogestrel, Contraceptive Agents, Female, Drug Implants. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To identify factors associated with the need for a deep etonogestrel contraceptive implant removal as compared to superficial removal. STUDY DESIGN: We conducted a retrospective cohort study of patients undergoing contraceptive implant removal from January 2014 to January 2023. We extracted key patient characteristics from electronic health record review and compared patients requiring deep removal versus routine superficial removal using Chi-squared, Fischer's exact, and Mann-Whitney U test. A multivariate logistic regression identified variables associated with increased odds of requiring a deep implant removal. RESULTS: The deep and superficial removal groups included 162 and 585 patients, respectively. Deep removal was associated with younger age at removal (median 25.0 vs 26.0 years, p = 0.005), lower body mass index (BMI) at insertion (median 23.2 kg/m2 vs 26.6 kg/m2, p = 0.024), BMI≥ 40 kg/m2 at removal (15.2% vs 7.0%, p = 0.007), weight gain during implant use (median 6.6 vs 1.8 kg, p ≤ 0.001), longer duration of use (median 36.0 vs 27.5 months, p < 0.001), implant exchange (37.3% vs 17.4%, p < 0.001), and insertion by non-physician (43.3% vs 19.3%, p < 0.001) or non-obstetrican and gynecologist (31.4% vs 11.8%, p < 0.001). Lower BMI at insertion (aOR 0.92, [95% CI 0.87-0.98]), weight gain during use (aOR 1.06 [95% CI 1.02-1.10]), and longer duration of use (aOR 1.05 [95% CI 1.02-1.07]) remained significantly associated with deep removal in regression analysis. CONCLUSION(S): We identified lower BMI at insertion, weight gain during use, and longer duration of use as independent factors associated with increased likelihood of needing a deep contraceptive implant removal. IMPLICATIONS: Clinicians should utilize proper technique when inserting contraceptive implants, especially in patients at risk for deep insertion, and ensure immediate referral to Centers of Experience for patients with non-palpable implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Device RemovalDesogestrelContraceptive Agents, FemaleDrug ImplantsHumansRetrospective StudiesFemaleAdultYoung AdultBody Mass IndexLogistic Models

Stichwörter der Autor:innen

ContraceptionContraceptive implantDeepNexplanonRemoval

Substanzen

DesogestreletonogestrelContraceptive Agents, FemaleDrug Implants

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Division of Family Planning, University of Colorado Anschutz Medical Campus, Aurora, CO, United States. Electronic address: paige.kendall@cuanschutz.edu.
  • Department of Obstetrics and Gynecology, Division of Family Planning, University of Colorado Anschutz Medical Campus, Aurora, CO, United States.
  • Department of Obstetrics, Gynecology and Reproductive Sciences, Division of Family Planning and Reproductive Sciences, Yale University School of Medicine, New Haven, CT, United States.

Zitieren

APA

Kendall, P. D., Bresnitz, W., Huang, J., Sheeder, J., & Lazorwitz, A. (2024). A retrospective analysis of factors associated with deep contraceptive implant removals compared to superficial removals. Contraception. https://doi.org/10.1016/j.contraception.2024.110486

Vancouver

Kendall PD, Bresnitz W, Huang J, Sheeder J, Lazorwitz A. A retrospective analysis of factors associated with deep contraceptive implant removals compared to superficial removals. Contraception. 2024. doi:10.1016/j.contraception.2024.110486

BibTeX
@article{Kendall2024,
  author = {Kendall, Paige D and Bresnitz, Wyanet and Huang, Jin and Sheeder, Jeanelle and Lazorwitz, Aaron},
  title = {A retrospective analysis of factors associated with deep contraceptive implant removals compared to superficial removals},
  journal = {Contraception},
  year = {2024},
  doi = {10.1016/j.contraception.2024.110486}
}
Kostenlos starten →