Deep implant removal: The impact of implant depth and positioning
International Journal of Gynecology & Obstetrics · 2025
DOI: 10.1002/ijgo.70675 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift International Journal of Gynecology & Obstetrics, 2025. Verfasst von Daniela Faranna und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gynecology, Sexual and Reproductive Health, and Climacteric Section, D. F. Santojanni Hospital, Buenos Aires, Argentina. Hauptthemen laut MEDLINE: Device Removal, Desogestrel, Drug Implants, Contraceptive Agents, Female. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Fundaçatilde;o de Amparo agrave; Pesquisa do Estado de Satilde;o Paulo, Fundação de Amparo à Pesquisa do Estado de São Paulo.
Abstract (Originalsprache)
Objective
This study assesses the factors associated with deep and complex implant placement, including the difficulties and need for surgical removal. Materials and Methods Our cross‐sectional study was conducted at two centers in Argentina and Brazil, with users of etonogestrel implant who required removal. Healthcare providers recorded implant depth, location, presence of fibrosis, and need for surgical removal.
Results
A total of 846 women were included, with a mean ± standard deviation age of 29.3 ± 7.4 years. Most implants (75.8%) were in an adequate location. We found that 91.4% of implants were palpable, while 16.5% were deeply placed. Surgical removal was required in 7.8% of the cases. After multivariate regression, we found that inadequate placement increased the likelihood of deep positioning by 17‐fold (odds ratio [OR] 17.05, 95% CI 9.69; 30, P < 0.001), while fibrosis increased this risk by 2.2‐fold (OR 2.27, 95% CI 1.23; 4.18, P < 0.001). Deep implants had a markedly increased likelihood of requiring surgical removal (OR 51.44, 95% CI 8.55; 309.55, P < 0.001), and fibrosis increased this risk by 9.66‐fold (OR 9.66, 95% CI 1.15; 81.39, P = 0.037).
Conclusion
Difficult implant removals, including surgical extractions, are strongly associated with inadequate placement and fibrosis. These factors significantly increase the complexity of removal, emphasizing the need for proper insertion training and early identification of high‐risk cases to reduce surgical interventions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Gynecology, Sexual and Reproductive Health, and Climacteric Section, D. F. Santojanni Hospital, Buenos Aires, Argentina.
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, Brazil.
ORCID-Profile: Daniela Faranna, Nadia Bergamo, Juliana de Toledo Piza Soares, Cassia R T Juliato, Luis Bahamondes
Förderung
- Fundaçatilde;o de Amparo agrave; Pesquisa do Estado de Satilde;o Paulo
- Fundação de Amparo à Pesquisa do Estado de São Paulo
Zitieren
APA
Faranna, D., Bergamo, N., de Toledo Piza Soares, J., Juliato, C. R. T., & Bahamondes, L. (2025). Deep implant removal: The impact of implant depth and positioning. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.70675
Vancouver
Faranna D, Bergamo N, de Toledo Piza Soares J, Juliato CRT, Bahamondes L. Deep implant removal: The impact of implant depth and positioning. International Journal of Gynecology & Obstetrics. 2025. doi:10.1002/ijgo.70675
BibTeX
@article{Faranna2025,
author = {Faranna, Daniela and Bergamo, Nadia and de Toledo Piza Soares, Juliana and Juliato, Cassia R T and Bahamondes, Luis},
title = {Deep implant removal: The impact of implant depth and positioning},
journal = {International Journal of Gynecology & Obstetrics},
year = {2025},
doi = {10.1002/ijgo.70675}
}
EUVIMED