EUVIMEDEUVIMED entdecken
Open Access

Impact of aortic valve leaflets calcium volume and distribution on Post-TAVR conduction abnormalities

Symon Reza, Brandon Kovarovic, Danny Bluestein

Computer Methods and Programs in Biomedicine · 2026-10 · 285 · 109543

DOI: 10.1016/j.cmpb.2026.109543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2026-10. Verfasst von Symon Reza und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA. Hauptthemen laut MEDLINE: Aortic Valve, Transcatheter Aortic Valve Replacement, Calcium, Calcinosis. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transcatheter aortic valve replacement (TAVR) is increasingly used to treat aortic stenosis, including in low-risk patients. However, post-procedural cardiac conduction abnormalities (CCA), often requiring permanent pacemaker implantation (PPI), remain a concern. This study investigates how the volume and distribution of aortic leaflet calcium deposits influence the risk of post-TAVR CCA.

Methods

An electromechanically coupled four-chamber beating heart model was used to simulate TAVR with a self-expandable Evolut® 26 mm device. Five virtual patient scenarios were modeled with varying calcium volumes and distributions: no calcium, uniform distribution (3 Calc), and isolated calcification on the left coronary leaflet (LCL), right coronary leaflet (RCL), or non-coronary leaflet (NCL). Electrical conduction was simulated using a monodomain model and coupled with structural mechanics to evaluate tissue-device interactions. Metrics included principal stress, contact pressure, and contact pressure index (CPI) over three cardiac cycles.

Results

Larger calcium volumes and specific leaflet distributions increased stress and contact pressure near the atrioventricular node. The LCL model exhibited the highest mechanical stress and peak contact pressure (13.1 kPa), while the NCL model showed the lowest (6.42 kPa). The RCL model had intermediate values. Elevated contact pressure and stress in the LCL case suggest an increased risk of conduction disruption and PPI.

Conclusion

Leaflet calcium deposit volume and distribution significantly influence mechanical stress and contact dynamics near the conduction system following TAVR. These insights support the integration of clinical data, such as leaflet calcium volume and distribution into pre-procedural planning to personalize risk assessment and improve patient outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic ValveTranscatheter Aortic Valve ReplacementCalciumCalcinosisHeart Conduction SystemHumansAortic Valve StenosisComputer SimulationStress, MechanicalModels, Cardiovascular

Stichwörter der Autor:innen

Conduction abnormalityFEALeaflet calcificationLiving Heart ModelPPITAVR

Substanzen

Calcium

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.
  • Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA. Electronic address: danny.bluestein@stonybrook.edu.

Förderung

  • NIBIB NIH HHS
  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Reza, S., Kovarovic, B., & Bluestein, D. (2026). Impact of aortic valve leaflets calcium volume and distribution on Post-TAVR conduction abnormalities. Computer Methods and Programs in Biomedicine, 285, 109543. https://doi.org/10.1016/j.cmpb.2026.109543

Vancouver

Reza S, Kovarovic B, Bluestein D. Impact of aortic valve leaflets calcium volume and distribution on Post-TAVR conduction abnormalities. Computer Methods and Programs in Biomedicine. 2026;285:109543. doi:10.1016/j.cmpb.2026.109543

BibTeX
@article{Reza2026,
  author = {Reza, Symon and Kovarovic, Brandon and Bluestein, Danny},
  title = {Impact of aortic valve leaflets calcium volume and distribution on Post-TAVR conduction abnormalities},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2026},
  volume = {285},
  pages = {109543},
  doi = {10.1016/j.cmpb.2026.109543}
}
Kostenlos starten →