ACURATE neo2 Versus SAPIEN 3 Ultra Transcatheter Heart Valve in Severe Aortic Valve Calcification: A Propensity-Matched Analysis
Circulation: Cardiovascular Interventions · 2024
DOI: 10.1161/circinterventions.123.013608 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Circulation: Cardiovascular Interventions, 2024. Verfasst von Clemens Eckel und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.). Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Heart Valve Prosthesis, Aortic Valve, Prosthesis Design. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm 2 ) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, −4.4 to −7.2]; P =0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, −5.0% [95% CI, −13.2 to 3.1]; P =0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0–13.9]; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany (C.E., D.S., C.G., V.T., H.M., J.B.).
- Department of Cardiology, University of Oldenburg, Germany (C.E., A.E., J.B.).
- Departments of Cardiology (W.-K.K., M.R.), Kerckhoff Heart Center, Bad Nauheim, Germany.
- Cardiac Surgery (W.-K.K., M.R., E.I.C., Y.-H.C.), Kerckhoff Heart Center, Bad Nauheim, Germany.
- Department of Cardiac Surgery, University of Kiel, Germany (C.G.).
- Department of Cardiac Surgery, St. Johannes Hospital, Dortmund, Germany (G.D.).
ORCID-Profile: Clemens Eckel, Won-Keun Kim, Vedat Tiyerili, Guido Dohmen, Yeong-Hoon Choi, Johannes Blumenstein
Zitieren
APA
Eckel, C., Kim, W. K., Sötemann, D., Grothusen, C., Tiyerili, V., Dohmen, G., Renker, M., Charitos, E. I., Hamm, C. W., Choi, Y. H., Elsässer, A., Möllmann, H., & Blumenstein, J. (2024). ACURATE neo2 Versus SAPIEN 3 Ultra Transcatheter Heart Valve in Severe Aortic Valve Calcification: A Propensity-Matched Analysis. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.123.013608
Vancouver
Eckel C, Kim WK, Sötemann D, Grothusen C, Tiyerili V, Dohmen G, et al. ACURATE neo2 Versus SAPIEN 3 Ultra Transcatheter Heart Valve in Severe Aortic Valve Calcification: A Propensity-Matched Analysis. Circulation: Cardiovascular Interventions. 2024. doi:10.1161/circinterventions.123.013608
BibTeX
@article{Eckel2024,
author = {Eckel, Clemens and Kim, Won-Keun and Sötemann, Dagmar and Grothusen, Christina and Tiyerili, Vedat and Dohmen, Guido and Renker, Matthias and Charitos, Efstratios I and Hamm, Christian W and Choi, Yeong-Hoon and Elsässer, Albrecht and Möllmann, Helge and Blumenstein, Johannes},
title = {ACURATE neo2 Versus SAPIEN 3 Ultra Transcatheter Heart Valve in Severe Aortic Valve Calcification: A Propensity-Matched Analysis},
journal = {Circulation: Cardiovascular Interventions},
year = {2024},
doi = {10.1161/circinterventions.123.013608}
}