Noise-Pressure Constrained Liutex method for robust vortex identification in 4D Flow MRI of abdominal aortic aneurysms
Computer Methods and Programs in Biomedicine · 2026-09 · 284 · 109455
DOI: 10.1016/j.cmpb.2026.109455 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2026-09. Verfasst von Chengxin Weng und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular Surgery, Department of General Surgery and West China Biomedical Big Data Center, West China Hospital, Sichuan University, Cheng…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Magnetic Resonance Imaging. Die Arbeit nennt 53 Literaturangaben. Gefördert von: Science and Technology Department of Sichuan Province, Sichuan University, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
INTRODUCTION Accurate identification of vortices is critical for predicting the rupture risk of abdominal aortic aneurysms (AAA). However, existing vortex identification methods perform poorly in noisy 4D Flow MRI data. This study aims to develop a robust vortex identification framework to address these limitations. METHODS A new vortex identification method based on Liutex method is proposed that integrates relative pressure information and divergence-based noise estimation to enhance the accuracy and robustness of vortex identification in noisy environments. The performance of the proposed method was validated against conventional techniques (vorticity, Q-criterion, Δ-criterion) and original Liutex using 4D Flow MRI data from 10 AAA patients, with the Fβ score as the evaluation metric. RESULTS Qualitative visualization and quantitative analysis demonstrated the superior performance of the Noise-Pressure Constrained Liutex (NPC-Liutex) method. It achieved clearer delineation of vortical structures across diverse hemodynamic patterns, with significantly higher Fβ scores (average improvement: 0.058), lower spatial entropy (average improvement: 65.8%) and lower false identification rates (average reduced false identification: 78.6%) compared to existing methods. CONCLUSION The NPC-Liutex method enables reliable extraction of vortical structures, accurate quantification of vortex intensity, and robust tracking of their dynamic evolution in AAA. By addressing noise sensitivity and shear contamination, this approach offers a clinically viable tool for enhancing hemodynamic risk assessment in AAA using 4D Flow MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Vascular Surgery, Department of General Surgery and West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Department of General Surgery 1 (Hepato-Pancreato-…
- Biofluid Lab, Sichuan University-Pittsburgh Institute, Sichuan University, Chengdu, Sichuan, China.
- Division of Vascular Surgery, Department of General Surgery and West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Biofluid Lab, Sichuan University-Pittsburgh Instit…
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
- Division of Vascular Surgery, Department of General Surgery and West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China; Med-X Center for Informatics, Sichuan University,…
Förderung
- Science and Technology Department of Sichuan Province
- Sichuan University
- Fundamental Research Funds for the Central Universities
- University of Electronic Science and Technology of China
- West China Hospital, Sichuan University
- National Natural Science Foundation of China
Zitieren
APA
Weng, C., He, D., Cheng, S., Yuan, D., Wang, T., Zeng, W., Luo, Y., Wang, J., Li, K., & Qiu, Y. (2026). Noise-Pressure Constrained Liutex method for robust vortex identification in 4D Flow MRI of abdominal aortic aneurysms. Computer Methods and Programs in Biomedicine, 284, 109455. https://doi.org/10.1016/j.cmpb.2026.109455
Vancouver
Weng C, He D, Cheng S, Yuan D, Wang T, Zeng W, et al. Noise-Pressure Constrained Liutex method for robust vortex identification in 4D Flow MRI of abdominal aortic aneurysms. Computer Methods and Programs in Biomedicine. 2026;284:109455. doi:10.1016/j.cmpb.2026.109455
BibTeX
@article{Weng2026,
author = {Weng, Chengxin and He, Daiyang and Cheng, Siquan and Yuan, Ding and Wang, Tiehao and Zeng, Wen and Luo, Yi and Wang, Jiarong and Li, Kang and Qiu, Yue},
title = {Noise-Pressure Constrained Liutex method for robust vortex identification in 4D Flow MRI of abdominal aortic aneurysms},
journal = {Computer Methods and Programs in Biomedicine},
year = {2026},
volume = {284},
pages = {109455},
doi = {10.1016/j.cmpb.2026.109455}
}
EUVIMED