EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated intravascular ultrasound image processing and quantification of coronary artery anomalies: The AIVUS-CAA software

Anselm W Stark, Pooya Mohammadi Kazaj, Sebastian Balzer, Marc Ilic, Manuel Bergamin, Ryota Kakizaki, Andreas Giannopoulos, Andreas Haeberlin, Lorenz Räber, Isaac Shiri, Christoph Gräni

Computer Methods and Programs in Biomedicine · 2025

DOI: 10.1016/j.cmpb.2025.109065 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025. Verfasst von Anselm W Stark und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Switzerland; Graduate School for Cellular and Biomedical Science…. Hauptthemen laut MEDLINE: Software, Ultrasonography, Interventional, Image Processing, Computer-Assisted, Coronary Vessel Anomalies. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVE: Coronary artery anomalies (CAA) with an intramural course are associated with elevated risks of ischemia and sudden cardiac death under stress. Intravascular ultrasound (IVUS) is essential for assessing coronary vessel dynamics in these patients. However, the rarity of such anomalies, along with unique geometric changes in the intramural course and ostium, complicates image analysis, leading to inconsistencies and time-consuming evaluations. Our developed executable, zero/low-code software addresses these limitations by providing automated lumen segmentation and cardiac phase identification in IVUS images acquired during rest and stress protocols. METHODS: The software includes: (1) Automated segmentation of lumen contours trained on 9,418 frames (developed by using human in the loop active learning process) validated on 691 frames and tested on 632 frames, IVUS frames from 76 patients (152 studies) with right CAA using a deep learning (DL) model; (2) Extraction of systolic and diastolic frames via a dual-gating approach combining image- and contour-based methods; and (3) A graphical user interface enabling manual correction of the results. The gating module was validated using a custom flow-loop simulating patient-specific hemodynamics, while segmentation accuracy was assessed via intraclass correlation coefficient (ICC) analysis comparing AI-generated contours with those delineated by experienced readers. RESULTS: The DL model achieved a mean Dice score of 0.91 (SD: 0.08), sensitivity of 0.95 (SD: 0.12), and specificity of 1.00 (SD: 0.00) on the test set. ICC values for lumen area measurements were 1.00 (95%CI: 1.00-1.00) for rest and 1.00 (95%CI: 1.00-1.00) for stress conditions. The gating module demonstrated excellent reproducibility for identifying systolic and diastolic frames under both conditions (ICC = 1.00 for all). CONCLUSIONS: AIVUS-CAA offers a reliable, automated tool for precise IVUS analysis at rest and during stress, enhancing the evaluation of geometrical changes of coronary vessels in CAA patients and enabling efficient clinical analysis in a streamlined workflow.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SoftwareUltrasonography, InterventionalImage Processing, Computer-AssistedCoronary Vessel AnomaliesCoronary VesselsHumansDeep LearningReproducibility of ResultsAutomationAlgorithmsFemaleMaleMiddle Aged

Stichwörter der Autor:innen

AAOCAACAOSCAADeep learningIVUSImage-based gatingSegmentationSoftware

Autor:innen und Institutionen

  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Switzerland; Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland.
  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Switzerland.
  • Department of Nuclear Medicine, Cardiac Imaging, Zurich University Hospital, University of Zurich, Switzerland.
  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Switzerland. Electronic address: christoph.graeni@insel.ch.

Förderung

  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Zitieren

APA

Stark, A. W., Mohammadi Kazaj, P., Balzer, S., Ilic, M., Bergamin, M., Kakizaki, R., Giannopoulos, A., Haeberlin, A., Räber, L., Shiri, I., & Gräni, C. (2025). Automated intravascular ultrasound image processing and quantification of coronary artery anomalies: The AIVUS-CAA software. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2025.109065

Vancouver

Stark AW, Mohammadi Kazaj P, Balzer S, Ilic M, Bergamin M, Kakizaki R, et al. Automated intravascular ultrasound image processing and quantification of coronary artery anomalies: The AIVUS-CAA software. Computer Methods and Programs in Biomedicine. 2025. doi:10.1016/j.cmpb.2025.109065

BibTeX
@article{Stark2025,
  author = {Stark, Anselm W and Mohammadi Kazaj, Pooya and Balzer, Sebastian and Ilic, Marc and Bergamin, Manuel and Kakizaki, Ryota and Giannopoulos, Andreas and Haeberlin, Andreas and Räber, Lorenz and Shiri, Isaac and Gräni, Christoph},
  title = {Automated intravascular ultrasound image processing and quantification of coronary artery anomalies: The AIVUS-CAA software},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2025},
  doi = {10.1016/j.cmpb.2025.109065}
}
Kostenlos starten →