EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

A comparative analysis of deep learning-based location-adaptive threshold method software against other commercially available software

Daebeom Park, Eun-Ah Park, Baren Jeong, Whal Lee

The International Journal of Cardiovascular Imaging · 2024

DOI: 10.1007/s10554-024-03099-7 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Daebeom Park und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Medical Sciences, Seoul National University College of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Deep Learning, Coronary Artery Disease, Coronary Angiography, Software. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Seoul National University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automatic segmentation of the coronary artery using coronary computed tomography angiography (CCTA) images can facilitate several analyses related to coronary artery disease (CAD). Accurate segmentation of the lumen or plaque region is one of the most important factors. This study aimed to analyze the performance of the coronary artery segmentation of a software platform with a deep learning-based location-adaptive threshold method (DL-LATM) against commercially available software platforms using CCTA. The dataset from intravascular ultrasound (IVUS) of 26 vessel segments from 19 patients was used as the gold standard to evaluate the performance of each software platform. Statistical analyses (Pearson correlation coefficient [PCC], intraclass correlation coefficient [ICC], and Bland-Altman plot) were conducted for the lumen or plaque parameters by comparing the dataset of each software platform with IVUS. The software platform with DL-LATM showed the bias closest to zero for detecting lumen volume (mean difference = -9.1 mm 3 , 95% confidence interval [CI] = -18.6 to 0.4 mm 3 ) or area (mean difference = -0.72 mm 2 , 95% CI = -0.80 to -0.64 mm 2 ) with the highest PCC and ICC. Moreover, lumen or plaque area in the stenotic region was analyzed. The software platform with DL-LATM showed the bias closest to zero for detecting lumen (mean difference = -0.07 mm 2 , 95% CI = -0.16 to 0.02 mm 2 ) or plaque area (mean difference = 1.70 mm 2 , 95% CI = 1.37 to 2.03 mm 2 ) in the stenotic region with significantly higher correlation coefficient than other commercially available software platforms ( p < 0.001). The result shows that the software platform with DL-LATM has the potential to serve as an aiding system for CAD evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningCoronary Artery DiseaseCoronary AngiographySoftwarePredictive Value of TestsComputed Tomography AngiographyCoronary VesselsRadiographic Image Interpretation, Computer-AssistedUltrasonography, InterventionalPlaque, AtheroscleroticHumansReproducibility of ResultsFemaleMaleMiddle AgedAgedRetrospective Studies

Stichwörter der Autor:innen

Automatic segmentationCoronary artery diseaseCoronary computed tomography angiographyDeep learning-based location-adaptive threshold methodSoftware platform

Autor:innen und Institutionen

  • Department of Clinical Medical Sciences, Seoul National University College of Medicine, Seoul, Korea.
  • Department of Radiology, Seoul National University Hospital, Seoul, Korea.
  • Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
  • Department of Radiology, Seoul National University Hospital, Seoul, Korea. whal.lee@gmail.com.
  • Department of Radiology, Seoul National University College of Medicine, Seoul, Korea. whal.lee@gmail.com.
  • Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea. whal.lee@gmail.com.

Förderung

  • Seoul National University Hospital

Zitieren

APA

Park, D., Park, E. A., Jeong, B., & Lee, W. (2024). A comparative analysis of deep learning-based location-adaptive threshold method software against other commercially available software. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03099-7

Vancouver

Park D, Park EA, Jeong B, Lee W. A comparative analysis of deep learning-based location-adaptive threshold method software against other commercially available software. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03099-7

BibTeX
@article{Park2024,
  author = {Park, Daebeom and Park, Eun-Ah and Jeong, Baren and Lee, Whal},
  title = {A comparative analysis of deep learning-based location-adaptive threshold method software against other commercially available software},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2024},
  doi = {10.1007/s10554-024-03099-7}
}
Kostenlos starten →