TD-STrans: Tri-domain sparse-view CT reconstruction based on sparse transformer
Computer Methods and Programs in Biomedicine · 2025-03 · 260 · 108575
DOI: 10.1016/j.cmpb.2024.108575 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025-03. Verfasst von Yu Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information and Communication Engineering, North University of China, Taiyuan 030051, China; The State Key Lab for Electronic Testing T…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 63 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVE: Sparse-view computed tomography (CT) speeds up scanning and reduces radiation exposure in medical diagnosis. However, when the projection views are severely under-sampled, deep learning-based reconstruction methods often suffer from over-smoothing of the reconstructed images due to the lack of high-frequency information. To address this issue, we introduce frequency domain information into the popular projection-image domain reconstruction, proposing a Tri-Domain sparse-view CT reconstruction model based on Sparse Transformer (TD-STrans). METHODS: TD-STrans integrates three essential modules: the projection recovery module completes the sparse-view projection, the Fourier domain filling module mitigates artifacts and over-smoothing by filling in missing high-frequency details; the image refinement module further enhances and preserves image details. Additionally, a multi-domain joint loss function is designed to simultaneously enhance the reconstruction quality in the projection domain, image domain, and frequency domain, thereby further improving the preservation of image details. RESULTS: The results of simulation experiments on the lymph node dataset and real experiments on the walnut dataset consistently demonstrate the effectiveness of TD-STrans in artifact removal, suppression of over-smoothing, and preservation of structural fidelity. CONCLUSION: The reconstruction results of TD-STrans indicate that sparse transformer across multiple domains can alleviate over-smoothing and detail loss caused by reduced views, offering a novel solution for ultra-sparse-view CT imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Information and Communication Engineering, North University of China, Taiyuan 030051, China; The State Key Lab for Electronic Testing Technology, North University of China, Taiyuan 030051, China.
- The State Key Lab for Electronic Testing Technology, North University of China, Taiyuan 030051, China; Department of computer science and technology, North University of China, Taiyuan 030051, China.
- Department of Information and Communication Engineering, North University of China, Taiyuan 030051, China; The State Key Lab for Electronic Testing Technology, North University of China, Taiyuan 030051, China. Electroni…
Zitieren
APA
Li, Y., Sun, X., Wang, S., Guo, L., Qin, Y., Pan, J., & Chen, P. (2025). TD-STrans: Tri-domain sparse-view CT reconstruction based on sparse transformer. Computer Methods and Programs in Biomedicine, 260, 108575. https://doi.org/10.1016/j.cmpb.2024.108575
Vancouver
Li Y, Sun X, Wang S, Guo L, Qin Y, Pan J, et al. TD-STrans: Tri-domain sparse-view CT reconstruction based on sparse transformer. Computer Methods and Programs in Biomedicine. 2025;260:108575. doi:10.1016/j.cmpb.2024.108575
BibTeX
@article{Li2025,
author = {Li, Yu and Sun, Xueqin and Wang, Sukai and Guo, Lina and Qin, Yingwei and Pan, Jinxiao and Chen, Ping},
title = {TD-STrans: Tri-domain sparse-view CT reconstruction based on sparse transformer},
journal = {Computer Methods and Programs in Biomedicine},
year = {2025},
volume = {260},
pages = {108575},
doi = {10.1016/j.cmpb.2024.108575}
}
EUVIMED