In silico data-based comparison of the accuracy and error source of various methods for noninvasively estimating central aortic blood pressure
Computer Methods and Programs in Biomedicine · 2024
DOI: 10.1016/j.cmpb.2024.108450 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Computer Methods and Programs in Biomedicine, 2024. Verfasst von Xujie Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Mechanics, School of Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Computer Simulation, Algorithms, Blood Pressure Determination, Aorta. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: Ministry of Education and Science of the Russian Federation, National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVES: The higher clinical significance of central aortic blood pressure (CABP) compared to peripheral blood pressures has been extensively demonstrated. Accordingly, many methods for noninvasively estimating CABP have been proposed. However, there still lacks a systematic comparison of existing methods, especially in terms of how they differ in the ability to tolerate individual differences or measurement errors. The present study was designed to address this gap. METHODS: A large-scale 'virtual subject' dataset (n = 600) was created using a computational model of the cardiovascular system, and applied to examine several classical CABP estimation methods, including the direct method, generalized transfer function (GTF) method, n-point moving average (NPMA) method, second systolic pressure of periphery (SBP2) method, physical model-based wave analysis (MBWA) method, and suprasystolic cuff-based waveform reconstruction (SCWR) method. The errors of CABP estimation were analyzed and compared among methods with respect to the magnitude/distribution, correlations with physiological/hemodynamic factors, and sensitivities to noninvasive measurement errors. RESULTS: The errors of CABP estimation exhibited evident inter-method differences in terms of the mean and standard deviation (SD). Relatively, the estimation errors of the methods adopting pre-trained algorithms (i.e., the GTF and SCWR methods) were overall smaller and less sensitive to variations in physiological/hemodynamic conditions and random errors in noninvasive measurement of brachial arterial blood pressure (used for calibrating peripheral pulse wave). The performances of all the methods worsened following the introduction of random errors to peripheral pulse wave (used for deriving CABP), as characterized by the enlarged SD and/or increased mean of the estimation errors. Notably, the GTF and SCWR methods did not exhibit a better capability of tolerating pulse wave errors in comparison with other methods. CONCLUSIONS: Classical noninvasive methods for estimating CABP were found to differ considerably in both the accuracy and error source, which provided theoretical evidence for understanding the specific advantages and disadvantages of each method. Knowledge about the method-specific error source and sensitivities of errors to different physiological/hemodynamic factors may contribute as theoretical references for interpreting clinical observations and exploring factors underlying large estimation errors, or provide guidance for optimizing existing methods or developing new methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering Mechanics, School of Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
- Department of Cardiology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
- School of Gongli Hospital Medical Technology, University of Shanghai for Science and Technology, Shanghai, China; School of Mechanical Engineering, University of Shanghai for science and Technology, Shanghai, China.
- Department of Engineering Mechanics, School of Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai, China; World-Class Research Center "Digital Biodesign and Personalized Healthcare", Sechenov First Mos…
Förderung
- Ministry of Education and Science of the Russian Federation
- National Natural Science Foundation of China
Zitieren
APA
Zhang, X., Li, Z., Zhang, Z., Wang, T., & Liang, F. (2024). In silico data-based comparison of the accuracy and error source of various methods for noninvasively estimating central aortic blood pressure. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2024.108450
Vancouver
Zhang X, Li Z, Zhang Z, Wang T, Liang F. In silico data-based comparison of the accuracy and error source of various methods for noninvasively estimating central aortic blood pressure. Computer Methods and Programs in Biomedicine. 2024. doi:10.1016/j.cmpb.2024.108450
BibTeX
@article{Zhang2024,
author = {Zhang, Xujie and Li, Zhaojun and Zhang, Zhi and Wang, Tianqi and Liang, Fuyou},
title = {In silico data-based comparison of the accuracy and error source of various methods for noninvasively estimating central aortic blood pressure},
journal = {Computer Methods and Programs in Biomedicine},
year = {2024},
doi = {10.1016/j.cmpb.2024.108450}
}
EUVIMED