Fachartikel in der Zeitschrift Clinical Oncology, 2026-12. Verfasst von S Singh und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Amrita School of Medicine, Amrita Vishwa Vidyapeetham, Faridabad, Haryana, India. Electronic address: sandeep.singh…. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
AIMS: Deep inspiration breath-hold (DIBH) reduces cardiac exposure during left-sided breast radiotherapy; however, treatment-day cardiac dose may differ from the planned dose because of variations in respiratory reproducibility and anatomy. The aim of this study was to develop and validate a framework for predicting fraction-level cardiac dose variation using routinely acquired respiratory, anatomical, and dosimetric information. MATERIALS AND METHODS: A retrospective cohort of 150 patients treated with postmastectomy DIBH VMAT (volumetric modulated arc therapy) was analyzed. Models were developed using a 30-patient development cohort with patient-wise-nested cross-validation, externally validated in 20 independent patients using cone-beam CT-derived synthetic CT dose recalculation, and applied to a 100-patient deployment cohort. Separate models predicted deviation from planned per-fraction mean heart dose (ΔMHD) and left anterior descending coronary artery dose (ΔLADCA D0.03 cc) using treatment-day real-time position management (RPM)--derived respiratory features, planning computed tomography (CT)-derived geometric variables, and plan-derived dosimetric parameters. SHAP-based analysis was performed to identify influential predictors. RESULTS: The final Gradient Boosting model for ΔMHD achieved an internal validation mean absolute error (MAE) of 0.541 ± 0.035 centigray (cGy) and coefficient of determination (R2) of 0.642 ± 0.069. The Ridge Regression model for left anterior descending coronary artery (ΔLADCA) achieved an MAE of 23.413 ± 1.617 cGy and R2 of 0.413 ± 0.082. External validation demonstrated good agreement for ΔMHD (MAE 0.58 cGy, R2 = 0.641), whereas ΔLADCA showed lower performance (MAE 24.14 cGy, R2 = 0.435). Stability index and baseline drift were key predictors. CONCLUSION: Treatment-day-respiratory characteristics combined with anatomical and dosimetric variables can estimate fraction-level cardiac dose variation during DIBH radiotherapy. The framework may support verification-based clinical review, with further validation required before implementation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Amrita School of Medicine, Amrita Vishwa Vidyapeetham, Faridabad, Haryana, India. Electronic address: sandeep.singh82a@gmail.com.
- Department of Radiation Oncology, Dr. B. Borooah Cancer Institute, Guwahati, Assam India. Electronic address: supratiksen494@gmail.com.
- Department of Radiation Oncology, Dharamshila Narayana Super Speciality Hospital, New Delhi, India.
- Department of Physics, GLA University, Mathura, Uttar Pradesh, India; Department of Radiation Oncology, Andromeda Cancer Hospital, Kundli, Sonipat, Haryana, India. Electronic address: d.vashisht700@gmail.com.
- Department of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India. Electronic address: manindra.drp44@gmail.com.
- Department of Physics, GLA University, Mathura, Uttar Pradesh, India; Department of Radiation Oncology, Yatharth Super Speciality Hospital, Faridabad, Haryana, India. Electronic address: soniyapal2412@gmail.com.
Zitieren
APA
Singh, S., Sen, S., Singh, A. K., Dipesh, Bhushan, M., Pal, S., Mahipal, Ahmad, I., & Chufal, K. S. (2026). Respiratory Instability–driven Cardiac Dose Deviation in Postmastectomy Deep Inspiration Breath-hold Volumetric Modulated Arc Therapy (DIBH VMAT): Development and External Validation of a Respiratory-informed Predictive Framework. Clinical Oncology, 60, 104353. https://doi.org/10.1016/j.clon.2026.104353
Vancouver
Singh S, Sen S, Singh AK, Dipesh, Bhushan M, Pal S, et al. Respiratory Instability–driven Cardiac Dose Deviation in Postmastectomy Deep Inspiration Breath-hold Volumetric Modulated Arc Therapy (DIBH VMAT): Development and External Validation of a Respiratory-informed Predictive Framework. Clinical Oncology. 2026;60:104353. doi:10.1016/j.clon.2026.104353
BibTeX
@article{Singh2026,
author = {Singh, S and Sen, S and Singh, A K and Dipesh and Bhushan, M and Pal, S and Mahipal and Ahmad, I and Chufal, K S},
title = {Respiratory Instability–driven Cardiac Dose Deviation in Postmastectomy Deep Inspiration Breath-hold Volumetric Modulated Arc Therapy (DIBH VMAT): Development and External Validation of a Respiratory-informed Predictive Framework},
journal = {Clinical Oncology},
year = {2026},
volume = {60},
pages = {104353},
doi = {10.1016/j.clon.2026.104353}
}
EUVIMED