Machine Learning-based Prediction of Mean Heart Dose and Deep Inspiration Breath-hold Selection in Left-sided Breast Cancer Volumetric Modulated Arc Therapy Radiotherapy Planning

Deepali Patil, Mukesh Kumar Zope, Rishi Raj, Seema Devi

Journal of Medical Physics · 2026-01 · 51 (1) · 77-88

DOI: 10.4103/jmp.jmp_292_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Physics, online erschienen am 31.03.2026. Verfasst von Deepali Patil und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and State Cancer Institute, Indira Gandhi Institute of Medical Sciences, Patna, Bihar, India. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Deep inspiration breath-hold (DIBH) can reduce cardiac radiation exposure in left-sided breast cancer, but resource limitations necessitate appropriate patient selection.

Purpose

To develop and evaluate a machine learning-based tool for predicting heart mean dose and identifying patients who would benefit from DIBH using simple anatomical predictors in left-sided breast cancer. Materials and Methods: A retrospective study analyzed 120 patients’ treatment plans on free-breathing (FB) scans from left-sided postmastectomy breast cancer patients treated with volumetric modulated arc therapy (VMAT). All plans were generated using three techniques: VMAT 2-field plan (VMAT-2P), VMAT 4-field plan (VMAT-4P), and VMAT 5-field plan (VMAT-5P). Two anatomical predictors, maximum heart distance (MHD) and heart-to-PTV distance (HPD), were measured. Elastic Net regression was used for continuous dose prediction, whereas logistic regression was applied for binary classification of DIBH necessity, using a 5 Gy heart mean dose threshold. An independent cohort ( n = 25) with paired FB-DIBH scans validated predictions.

Results

In the validation cohort ( n = 25), DIBH reduced mean heart dose by 34% (1.72–1.86 Gy, P < 0.001 for both techniques) and decreased high-risk patients (>5 Gy) by 69%–80%. Strong correlations were observed between FB predictions and DIBH-achieved doses for anatomical parameters and VMAT-2P ( r = 0.667–0.720, P < 0.001), with moderate correlation for VMAT-4P ( r = 0.545, P = 0.005). In the independent test cohort from the model development dataset ( n = 24), Elastic Net achieved mean absolute errors of 0.81–1.02 Gy. Logistic regression demonstrated 87.5% accuracy with 83%–92% sensitivity and 83%–92% specificity for VMAT-2P and VMAT-4P (area under the curve [AUC]: 0.85–0.94). The VMAT-5P technique showed reduced classification performance (58.3% accuracy, AUC: 0.83).

Conclusions

Machine learning software demonstrated accurate prediction of mean heart dose during pre-planning for left-sided breast cancer, enabling informed DIBH selection for cardiac sparing based on simple anatomical metrics from FB computed tomography (CT) scans.

Schlagwörter

Stichwörter der Autor:innen

Breast cancer radiotherapyDeep inspiration breath holdHeart dose predictionMachine learning

Autor:innen und Institutionen

  • Department of Medical Physics and State Cancer Institute, Indira Gandhi Institute of Medical Sciences, Patna, Bihar, India.
  • Department of Information Systems, Indian Institute of Management Visakhapatnam, Visakhapatnam, Andhra Pradesh, India.
  • Department of Radiation Oncology, State Cancer Institute, Indira Gandhi Institute of Medical Sciences, Patna, Bihar, India.

Zitieren

APA

Patil, D., Zope, M. K., Raj, R., & Devi, S. (2026). Machine Learning-based Prediction of Mean Heart Dose and Deep Inspiration Breath-hold Selection in Left-sided Breast Cancer Volumetric Modulated Arc Therapy Radiotherapy Planning. Journal of Medical Physics, 51(1), 77-88. https://doi.org/10.4103/jmp.jmp_292_25

Vancouver

Patil D, Zope MK, Raj R, Devi S. Machine Learning-based Prediction of Mean Heart Dose and Deep Inspiration Breath-hold Selection in Left-sided Breast Cancer Volumetric Modulated Arc Therapy Radiotherapy Planning. Journal of Medical Physics. 2026;51(1):77-88. doi:10.4103/jmp.jmp_292_25

BibTeX
@article{Patil2026,
  author = {Patil, Deepali and Zope, Mukesh Kumar and Raj, Rishi and Devi, Seema},
  title = {Machine Learning-based Prediction of Mean Heart Dose and Deep Inspiration Breath-hold Selection in Left-sided Breast Cancer Volumetric Modulated Arc Therapy Radiotherapy Planning},
  journal = {Journal of Medical Physics},
  year = {2026},
  volume = {51},
  number = {1},
  pages = {77--88},
  doi = {10.4103/jmp.jmp_292_25}
}
Kostenlos starten →