EUVIMEDEUVIMED entdecken
Open Access

Dependence of cortical neuronal strength-duration properties on TMS pulse shape

Parvathi Menon, Nathan Pavey, Aman S Aberra, Mehdi A J van den Bos, Ruochen Wang, Matthew C Kiernan, Angel V Peterchev, Steve Vucic

Clinical Neurophysiology · 2023

DOI: 10.1016/j.clinph.2023.03.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Neurophysiology, 2023. Verfasst von Parvathi Menon und 7 weiteren Autor:innen. Beteiligte Einrichtung: Brain and Nerve Research Centre, Concord Clinical School, University of Sydney, Concord Hospital, Sydney, Australia. Hauptthemen laut MEDLINE: Transcranial Magnetic Stimulation, Neurons. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIMH NIH HHS, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The aim of present study was to explore the effects of different combinations of transcranial magnetic stimulation (TMS) pulse width and pulse shape on cortical strength-duration time constant (SDTC) and rheobase measurements. METHODS: Resting motor thresholds (RMT) at pulse widths (PW) of 30, 45, 60, 90 and 120 µs and M-ratios of 0.2, 0.1 and 0.025 were determined using figure-of-eight coil with initial posterior-to-anterior induced current. The M-ratio indicates the relative phases of the induced current with lower values signifying a more unidirectional stimulus. Strength-duration time constant (SDTC) and rheobase were estimated for each M-ratio and various PW combinations. Simulations of biophysically realistic cortical neuron models assessed underlying neuronal populations and physiological mechanisms mediating pulse shape effects on strength-duration properties. RESULTS: The M-ratio exerted significant effect on SDTC (F(2,44) = 4.386, P = 0.021), which was longer for M-ratio of 0.2 (243.4 ± 61.2 µs) compared to 0.025 (186.7 ± 52.5 µs, P = 0.034). Rheobase was significantly smaller when assessed with M-ratio 0.2 compared to 0.025 (P = 0.026). SDTC and rheobase values were most consistent with pulse width sets of 30/45/60/90/120 µs, 30/60/90/120 µs, and 30/60/120 µs. Simulation studies indicated that isolated pyramidal neurons in layers 2/3, 5, and large basket-cells in layer 4 exhibited SDTCs comparable to experimental results. Further, simulation studies indicated that reducing transient Na+ channel conductance increased SDTC with larger increases for higher M-ratios. CONCLUSIONS: Cortical strength-duration curve properties vary with pulse shape, and the modulating effect of the hyperpolarising pulse phase on cortical axonal transient Na+ conductances could account for these changes, although a shift in the recruited neuronal populations may contribute as well. SIGNIFICANCE: The dependence of the cortical strength-duration curve properties on the TMS pulse shape and pulse width selection underscores the need for consistent measurement methods across studies and the potential to extract information about pathophysiological processes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcranial Magnetic StimulationNeuronsHumansAxonsHeart RateEvoked Potentials, MotorSarcosineThiocarbamates

Stichwörter der Autor:innen

RheobaseSDTCSodium channelStrength-duration time constantcTMS

Substanzen

sarcosine dithiocarbamateSarcosineThiocarbamates

Autor:innen und Institutionen

  • Brain and Nerve Research Centre, Concord Clinical School, University of Sydney, Concord Hospital, Sydney, Australia.
  • Department of Biological Sciences, Dartmouth College, Hanover, NH, USA.
  • Department of Biomedical Engineering, Duke University, Durham, NC, USA.
  • Brain and Mind Centre, University of Sydney, Australia.
  • Department of Biomedical Engineering, Duke University, Durham, NC, USA; Department of Psychiatry and Behavioural Sciences, Duke University, Durham, NC, USA; Department of Electrical and Computer Engineering, Duke Univer…
  • Brain and Nerve Research Centre, Concord Clinical School, University of Sydney, Concord Hospital, Sydney, Australia. Electronic address: steve.vucic@sydney.edu.au.

Förderung

  • NIMH NIH HHS
  • NINDS NIH HHS

Zitieren

APA

Menon, P., Pavey, N., Aberra, A. S., van den Bos, M. A. J., Wang, R., Kiernan, M. C., Peterchev, A. V., & Vucic, S. (2023). Dependence of cortical neuronal strength-duration properties on TMS pulse shape. Clinical Neurophysiology. https://doi.org/10.1016/j.clinph.2023.03.012

Vancouver

Menon P, Pavey N, Aberra AS, van den Bos MAJ, Wang R, Kiernan MC, et al. Dependence of cortical neuronal strength-duration properties on TMS pulse shape. Clinical Neurophysiology. 2023. doi:10.1016/j.clinph.2023.03.012

BibTeX
@article{Menon2023,
  author = {Menon, Parvathi and Pavey, Nathan and Aberra, Aman S and van den Bos, Mehdi A J and Wang, Ruochen and Kiernan, Matthew C and Peterchev, Angel V and Vucic, Steve},
  title = {Dependence of cortical neuronal strength-duration properties on TMS pulse shape},
  journal = {Clinical Neurophysiology},
  year = {2023},
  doi = {10.1016/j.clinph.2023.03.012}
}