Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
Investigative Opthalmology & Visual Science · 01.11.2023 · 64 (14) · 3
DOI: 10.1167/iovs.64.14.3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Opthalmology & Visual Science, erschienen am 01.11.2023. Verfasst von David A Berntsen und 9 weiteren Autor:innen. Beteiligte Einrichtung: College of Optometry, The University of Houston, Houston, Texas, United States. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Astigmatism, Color Vision, Lens, Crystalline. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS, NCATS NIH HHS.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Purpose
The purpose of this study was to evaluate the relationship between peripheral defocus and pupil size on axial growth in children randomly assigned to wear either single vision contact lenses, +1.50 diopter (D), or +2.50 D addition multifocal contact lenses (MFCLs).
Methods
Children 7 to 11 years old with myopia (-0.75 to -5.00 D; spherical component) and ≤1.00 D astigmatism were enrolled. Autorefraction (horizontal meridian; right eye) was measured annually wearing contact lenses centrally and ±20 degrees, ±30 degrees, and ±40 degrees from the line of sight at near and distance. Photopic and mesopic pupil size were measured. The effects of peripheral defocus, treatment group, and pupil size on the 3-year change in axial length were modeled using multiple variables that evaluated defocus across the retina.
Results
Although several peripheral defocus variables were associated with slower axial growth with MFCLs, they were either no longer significant or not meaningfully associated with eye growth after the treatment group was included in the model. The treatment group assignment better explained the slower eye growth with +2.50 MFCLs than peripheral defocus. Photopic and mesopic pupil size did not modify eye growth with the +2.50 MFCL (all P ≥ 0.37).
Conclusions
The optical signal causing slower axial elongation with +2.50 MFCLs is better explained by the lens type worn than by peripheral defocus. The signal might be something other than peripheral defocus, or there is not a linear dose-response relationship within treatment groups. We found no evidence to support pupil size as a criterion when deciding which myopic children to treat with MFCLs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- College of Optometry, The University of Houston, Houston, Texas, United States.
- College of Optometry, The Ohio State University, Columbus, Ohio, United States.
Förderung
- NEI NIH HHS
- NCATS NIH HHS
Zitieren
APA
Berntsen, D. A., Ticak, A., Sinnott, L. T., Chandler, M. A., Jones, J. H., Morrison, A., Jones-Jordan, L. A., Walline, J. J., Mutti, D. O., & BLINK Study Group (2023). Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study. Investigative Opthalmology & Visual Science, 64(14), 3. https://doi.org/10.1167/iovs.64.14.3
Vancouver
Berntsen DA, Ticak A, Sinnott LT, Chandler MA, Jones JH, Morrison A, et al. Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study. Investigative Opthalmology & Visual Science. 2023;64(14):3. doi:10.1167/iovs.64.14.3
BibTeX
@article{Berntsen2023,
author = {Berntsen, David A and Ticak, Anita and Sinnott, Loraine T and Chandler, Moriah A and Jones, Jenny Huang and Morrison, Ann and Jones-Jordan, Lisa A and Walline, Jeffrey J and Mutti, Donald O and BLINK Study Group, BLINK Study Group},
title = {Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study},
journal = {Investigative Opthalmology & Visual Science},
year = {2023},
volume = {64},
number = {14},
pages = {3},
doi = {10.1167/iovs.64.14.3}
}
EUVIMED