EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

The effect of back optic zone diameter on relative corneal refractive power distribution and corneal higher-order aberrations in orthokeratology

Na Li, Weiping Lin, Kailang Zhang, Bingqin Li, Qiang Su, Bei Du, Ruihua Wei

Contact Lens and Anterior Eye · 2023-02 · 46 (1) · 101755

DOI: 10.1016/j.clae.2022.101755 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2023-02. Verfasst von Na Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and S…. Hauptthemen laut MEDLINE: Contact Lenses, Orthokeratologic Procedures, Myopia. Die Arbeit wurde bisher 48-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare axial elongation, relative corneal refractive power (RCRP) distribution within the pupillary diameter, and corneal higher-order aberrations (HOAs) in myopic children wearing orthokeratology (ortho-k) lenses with different back optic zone diameters (BOZD). METHODS: Children aged 8-11 years were fitted with 5.0 or 6.2 mm-BOZD ortho-k lenses (groups A and B, respectively). Axial length (AL) and corneal topography were measured at baseline and during the annual visit. RCRP and corneal HOAs were compared between the two groups after one-year treatment. Multivariate linear regression analysis was performed to determine the association between AL elongation and RCRP parameters, corneal HOAs, and other variables between the groups. RESULTS: After one-year treatment, axial elongation was slower in group A than in group B, with a difference of 0.15 mm. Children in group A showed smaller treatment zone size, smaller 3/4X value (describing the distance from the apex RCRP profile rising to its three-quarter-peak level), greater RCRP sum value within the pupillary area, and higher increases in corneal total HOAs and horizontal coma (Z31). AL elongation was significantly correlated with baseline age, baseline spherical equivalent refraction (SER), treatment zone size, and 3/4X value. CONCLUSIONS: Ortho-k lenses designed with smaller BOZD increased myopia control efficacy, induced a steeper distribution of the RCRP profile within the pupillary diameter, and induced greater increases in corneal total HOAs and horizontal coma (Z31). Lens-induced RCRP profile within pupillary diameter, rising to its three-quarter-peak level at a smaller distance, may show a better myopia control effect.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contact LensesOrthokeratologic ProceduresMyopiaChildHumansComaCorneaCorneal TopographyRefraction, OcularAxial Length, Eye

Stichwörter der Autor:innen

Back optic zone diameterCorneal higher-order aberrationsMyopia controlOrthokeratologyRelative corneal refractive power

Autor:innen und Institutionen

  • Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin,…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, N., Lin, W., Zhang, K., Li, B., Su, Q., Du, B., & Wei, R. (2023). The effect of back optic zone diameter on relative corneal refractive power distribution and corneal higher-order aberrations in orthokeratology. Contact Lens and Anterior Eye, 46(1), 101755. https://doi.org/10.1016/j.clae.2022.101755

Vancouver

Li N, Lin W, Zhang K, Li B, Su Q, Du B, et al. The effect of back optic zone diameter on relative corneal refractive power distribution and corneal higher-order aberrations in orthokeratology. Contact Lens and Anterior Eye. 2023;46(1):101755. doi:10.1016/j.clae.2022.101755

BibTeX
@article{Li2023,
  author = {Li, Na and Lin, Weiping and Zhang, Kailang and Li, Bingqin and Su, Qiang and Du, Bei and Wei, Ruihua},
  title = {The effect of back optic zone diameter on relative corneal refractive power distribution and corneal higher-order aberrations in orthokeratology},
  journal = {Contact Lens and Anterior Eye},
  year = {2023},
  volume = {46},
  number = {1},
  pages = {101755},
  doi = {10.1016/j.clae.2022.101755}
}
Kostenlos starten →