Comparing sagittal heights calculated using corneal parameters and those measured with profilometry
Contact Lens and Anterior Eye · 2023-04 · 46 (2) · 101747
DOI: 10.1016/j.clae.2022.101747 ↗Kurz gefasst
Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2023-04. Verfasst von Javier Rojas Viñuela und 2 weiteren Autor:innen. Beteiligte Einrichtung: Natural Optics Balaguer, 25600 Balaguer, Lleida, Spain. Hauptthemen laut MEDLINE: Cornea, Contact Lenses, Hydrophilic. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Asuntos Económicos y Transformación Digital, Gobierno de España.
Abstract (Originalsprache)
PURPOSE: To compare the sagittal height of the anterior eye (OC-SAG) calculated using corneal parameters with the OC-SAG measured by profilometry. METHOD: Seventy right eyes of soft contact lens wearers measured with the ESP (Eaglet Eye, The Netherlands) after lens removal were retrospectively analyzed for this study. The OC-SAG of the eyes was calculated using mean k-values, eccentricity and the inner (corneal) radius obtained with the ESP for an 11-mm cord diameter. It was then extrapolated to chord diameters of 14, 14.5 and 15 mm. These values were compared with OC-SAG values obtained with the ESP for the same chord diameters. Additionally, the OC-SAG was calculated through the formula used by a lab that manufactures custom soft lenses (mark'ennovy, Madrid, Spain) and compared again with the values obtained using the ESP. RESULTS: Differences between calculated OC-SAG obviating the shape factor were 121 ± 44, 155 ± 105, 172 ± 117 and 189 ± 129 µm for chord diameters of 11, 14, 14.5 and 15 mm, respectively (p < 0.001). When the shape factor was included in the calculation, differences were 28 ± 48, 62 ± 102, 79 ± 113 and 96 ± 123 µm (p < 0.001). When the inner best fit sphere was used to estimate OC-SAG, differences were 34 ± 11, 0 ± 72, 17 ± 86 and 34 ± 99, respectively, with no significant differences for the 14 and 14.5 mm-chord diameters (p = 0.99 and 0.11, respectively). Correlation coefficients between OC-SAG calculated and measured OC-SAG ranged from 0.53 to 0.90 depending on the chord diameter used. When the mark'ennovy formula was used to calculate the OC-SAG as the lens diameter proposed by the formula, the difference was -47 ± 147 µm (p < 0.01). CONCLUSIONS: Differences between the OC-SAG calculated using corneal parameters and that measured with a profilometer are statistically and clinically significant, especially for large chord diameters. The impact of this on contact lens fitting should be addressed in future studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Natural Optics Balaguer, 25600 Balaguer, Lleida, Spain.
- Department of Ophthalmology, Vithas Medimar International Hospital, 03016 Alicante, Spain; Department of Optics, Pharmacology, and Anatomy, University of Alicante, Spain. Electronic address: david.pinyero@ua.es.
- Department of R&D, mark'ennovy Personalized Care, Madrid, Spain.
Förderung
- Ministerio de Asuntos Económicos y Transformación Digital, Gobierno de España
Zitieren
APA
Rojas Viñuela, J., Piñero, D. P., & Martínez, M. B. (2023). Comparing sagittal heights calculated using corneal parameters and those measured with profilometry. Contact Lens and Anterior Eye, 46(2), 101747. https://doi.org/10.1016/j.clae.2022.101747
Vancouver
Rojas Viñuela J, Piñero DP, Martínez MB. Comparing sagittal heights calculated using corneal parameters and those measured with profilometry. Contact Lens and Anterior Eye. 2023;46(2):101747. doi:10.1016/j.clae.2022.101747
BibTeX
@article{RojasViuela2023,
author = {Rojas Viñuela, Javier and Piñero, David P and Martínez, Mercedes Burgos},
title = {Comparing sagittal heights calculated using corneal parameters and those measured with profilometry},
journal = {Contact Lens and Anterior Eye},
year = {2023},
volume = {46},
number = {2},
pages = {101747},
doi = {10.1016/j.clae.2022.101747}
}
EUVIMED