EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY-NC-ND 4.0

Biomechanical performance of proximal tibia fracture plates: A review

Radovan Zdero, Pawel Brzozowski, Emil H Schemitsch

Chinese Journal of Traumatology · 2025

DOI: 10.1016/j.cjtee.2025.02.005 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Chinese Journal of Traumatology, 2025. Verfasst von Radovan Zdero und 2 weiteren Autor:innen. Beteiligte Einrichtung: London Health Sciences Centre Research Institute, London, Ontario, Canada. Hauptthemen laut MEDLINE: Bone Plates, Tibial Fractures, Fracture Fixation, Internal. Die Arbeit nennt 112 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Proximal fractures of the tibia (i.e., shin bone) are often treated using proximal tibia fracture plates (PTFPs) that are not always biomechanically optimal. This is a review of biomechanical papers that studied the effect of modifying PTFP plate and screw variables. METHODS: PubMed, Scopus, and Web of Science databases were searched for English-language papers published before February 2024 using the terms "biomechanics" plus "proximal or plateau" plus "tibia" plus "fracture or "plate." Eligibility criteria were applied: (1) biomechanical studies only; (2) optimization studies that systematically permutated plate or screw variables; (3) plate-and-screw fixation only; (4) intra-articular or extra-articular fractures. The papers were examined for implant variables such as plate geometry, plate material, screw number, etc., while papers were also examined for outcome metrics like interfragmentary motion, plate stress, overall stiffness, etc. RESULTS: The 52 eligible PTFP papers considered the biomechanical effect of plate geometry, material, hole type, number, and position, while screw variables included geometry, number, and angle. Outcome metrics were interfragmentary motion (0-22.53 mm or 0°-60.1°), bone stress (1-1170 MPa), plate stress (3-586 MPa), and screw stress (3-1613 MPa), bone stress under the plate (2-11 MPa), number of loading cycles to failure (11,500-1,000,000), overall stiffness (22-24,869 N/mm or 0.4-63.8 Nm/degree), and failure strength (259-14,387 N). Reviewed papers showed that a PTFP's biomechanical stability could be maximized by using 1 or 2 plates that were contoured, larger, locking, metal, and/or placed on the largest surface of the bone fragment(s), while head, kickstand, and/or shaft screws should be longer, thicker, solid, metal, and/or angled. But more future work could be done on the biomechanical effect of plate design (e.g., alternative materials), bone quality (e.g., normal vs. osteoporotic), loading mode (i.e., axial, bending, torsion), etc. CONCLUSIONS: PTFPs should have their plate and screw variables optimized to provide the best biomechanical performance and clinical outcomes, but more work is required to determine the optimal conditions. Engineers and surgeons may find this review beneficial for designing, analyzing, or utilizing PTFPs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesTibial FracturesFracture Fixation, InternalBiomechanical PhenomenaHumansBone Screws

Stichwörter der Autor:innen

BiomechanicsFracture platesOptimizationProximal tibiaReview

Autor:innen und Institutionen

  • London Health Sciences Centre Research Institute, London, Ontario, Canada.
  • London Health Sciences Centre Research Institute, London, Ontario, Canada. Electronic address: pawel.brzozowski@lhsc.on.ca.
  • London Health Sciences Centre Research Institute, London, Ontario, Canada; Division of Orthopaedic Surgery, Western University, London, Ontario, Canada.

Zitieren

APA

Zdero, R., Brzozowski, P., & Schemitsch, E. H. (2025). Biomechanical performance of proximal tibia fracture plates: A review. Chinese Journal of Traumatology. https://doi.org/10.1016/j.cjtee.2025.02.005

Vancouver

Zdero R, Brzozowski P, Schemitsch EH. Biomechanical performance of proximal tibia fracture plates: A review. Chinese Journal of Traumatology. 2025. doi:10.1016/j.cjtee.2025.02.005

BibTeX
@article{Zdero2025,
  author = {Zdero, Radovan and Brzozowski, Pawel and Schemitsch, Emil H},
  title = {Biomechanical performance of proximal tibia fracture plates: A review},
  journal = {Chinese Journal of Traumatology},
  year = {2025},
  doi = {10.1016/j.cjtee.2025.02.005}
}
Kostenlos starten →