EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Interfragmentary compression force and fixation stability of lateral tibial plateau fractures in normal and osteoporotic bones

Jiang Jiang iD, Daqiang Xu, Zhenhua Ji, Rui Jia, Fei Wang, Jinchuan Tan, Hong Hong, Jianyi Li

Journal of Orthopaedic Research · 2024

DOI: 10.1002/jor.25832 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2024. Verfasst von Jiang Jiang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translatio…. Hauptthemen laut MEDLINE: Finite Element Analysis, Tibial Fractures, Fracture Fixation, Internal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Key Research and Development Program of China, Natural Science Foundation of Guangdong Province, Special Project of Clinical Medicine of Natong University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lateral platform collapse in fixations of lateral tibial plateau fractures (TPFs) using either double‐lag screws fixation (DSF) or locking‐plate fixation (LPF) is not rare. This study aimed to explore the effect of enhancing the interfragmentary compression force (IFCF) on fixation stability in lateral TPFs in normal and osteoporotic bones using finite element analysis. Finite element models of DSF in normal bone and LPF in normal and osteoporotic bones were established to simulate the fixations of lateral TPF. After model validation, axial compressive forces of 500, 1000, 1500, and 2500 N to the tibial plateau along with an IFCF of 0, 100, 200, and 300 N were applied. The maximum axial micromotion of the lateral fragment (MAM‐LF), maximal translational micromotion of the lateral fragment (MTM‐LF), peak von Mises stress (VMS), and peak equivalent elastic strain of the lateral fragment (EES‐LF) were evaluated. The MAM‐LF showed a decreasing trend as the IFCF increased in all models. For DSF models, the peak VMS of implants increased as the IFCF increased when the axial loads were 500 and 1000 N. The peak EES‐LF decreased as the IFCF increased under axial loads of 1000, 1500, and 2500 N. For the normal and osteoporotic LPF models, the peak VMS of the implants decreased as the IFCF increased. Peak EES‐LF decreased as IFCF increased. In conclusion, enhancing IFCF was beneficial in improving the fixation stability of lateral TPF. The optimal IFCF for DSF and LPF should be as high as reasonably feasible.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisTibial FracturesFracture Fixation, InternalHumansBiomechanical PhenomenaBone PlatesOsteoporosisOsteoporotic FracturesBone ScrewsTibial Plateau Fractures

Stichwörter der Autor:innen

finite element analysisfixation stabilityinterfragmentary compression forcelateral tibial plateau fracturenormal and osteoporotic bones

Autor:innen und Institutionen

  • Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual & Reality Exper…
  • Department of Orthopedics, Affiliated Hospital 6 of Nantong University, Yancheng Third People's Hospital, Yancheng, China.
  • Department of Rehabilitation Medicine, Shandong Public Health Clinical Center, Shandong University, Jinan, China.
  • Department of Rehabilitation Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
  • Department of Anatomy, Nanchang Medical College, Nanchang, China.

ORCID-Profile: Jiang Jiang

Förderung

  • National Key Research and Development Program of China
  • Natural Science Foundation of Guangdong Province
  • Special Project of Clinical Medicine of Natong University

Zitieren

APA

Jiang, J., Xu, D., Ji, Z., Jia, R., Wang, F., Tan, J., Hong, H., & Li, J. (2024). Interfragmentary compression force and fixation stability of lateral tibial plateau fractures in normal and osteoporotic bones. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.25832

Vancouver

Jiang J, Xu D, Ji Z, Jia R, Wang F, Tan J, et al. Interfragmentary compression force and fixation stability of lateral tibial plateau fractures in normal and osteoporotic bones. Journal of Orthopaedic Research. 2024. doi:10.1002/jor.25832

BibTeX
@article{Jiang2024,
  author = {Jiang, Jiang and Xu, Daqiang and Ji, Zhenhua and Jia, Rui and Wang, Fei and Tan, Jinchuan and Hong, Hong and Li, Jianyi},
  title = {Interfragmentary compression force and fixation stability of lateral tibial plateau fractures in normal and osteoporotic bones},
  journal = {Journal of Orthopaedic Research},
  year = {2024},
  doi = {10.1002/jor.25832}
}
Kostenlos starten →