EUVIMEDEUVIMED entdecken
Leserbrief

Safety and Efficacy of Balloon-Expandable Transcatheter Aortic Valve Implantation in Patients With Extreme Horizontal Aorta

Masaaki Nakase, Daijiro Tomii, Fabien Praz, Stefan Stortecky, Jonas Lanz, David Reineke, Stephan Windecker, Thomas Pilgrim

Canadian Journal of Cardiology · 2024

DOI: 10.1016/j.cjca.2023.12.019 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Canadian Journal of Cardiology, 2024. Verfasst von Masaaki Nakase und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis, Heart Valve Prosthesis. Die Arbeit nennt 5 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Anatomical risk assessment based on pre-procedural multidetector computed tomography (MDCT) is key to preprocedural planning in patients undergoing transcatheter aortic valve implantation (TAVI). Horizontal aorta, is a challenging anatomical feature for device delivery and proper prosthesis positioning. Previous studies have suggested that the use of balloon-expandable valve (BEV) is preferred in patients with horizontal aorta1,2. However, few studies have adequately included patients with extreme horizontal aorta (≥70°), for which manufacturers have issued a warning2,3. Thus, we sought to investigate the impact of extreme horizontal aorta on procedural outcomes in patients undergoing TAVI with BEV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisHeart Valve ProsthesisHumansAortic ValveAortaTreatment OutcomeProsthesis Design

Autor:innen und Institutionen

  • Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland.
  • Department of Cardiac Surgery, Inselspital, University of Bern, Bern, Switzerland.
  • Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland. Electronic address: thomas.pilgrim@insel.ch.

Zitieren

APA

Nakase, M., Tomii, D., Praz, F., Stortecky, S., Lanz, J., Reineke, D., Windecker, S., & Pilgrim, T. (2024). Safety and Efficacy of Balloon-Expandable Transcatheter Aortic Valve Implantation in Patients With Extreme Horizontal Aorta. Canadian Journal of Cardiology. https://doi.org/10.1016/j.cjca.2023.12.019

Vancouver

Nakase M, Tomii D, Praz F, Stortecky S, Lanz J, Reineke D, et al. Safety and Efficacy of Balloon-Expandable Transcatheter Aortic Valve Implantation in Patients With Extreme Horizontal Aorta. Canadian Journal of Cardiology. 2024. doi:10.1016/j.cjca.2023.12.019

BibTeX
@article{Nakase2024,
  author = {Nakase, Masaaki and Tomii, Daijiro and Praz, Fabien and Stortecky, Stefan and Lanz, Jonas and Reineke, David and Windecker, Stephan and Pilgrim, Thomas},
  title = {Safety and Efficacy of Balloon-Expandable Transcatheter Aortic Valve Implantation in Patients With Extreme Horizontal Aorta},
  journal = {Canadian Journal of Cardiology},
  year = {2024},
  doi = {10.1016/j.cjca.2023.12.019}
}
Kostenlos starten →