EUVIMEDEUVIMED entdecken
MetaanalyseSystematische ÜbersichtOpen Access · CC BY 4.0

Impact of aortic angulation on outcomes in transcatheter aortic valve replacement with balloon-expandable and self-expanding valves: a systematic review and meta-analysis

Basma Badrawy Khalefa, Ahmed Reda Gonnah, Mazen Negmeldin Aly Yassin, Hossam Fayed, Moumen Arnaout, Mohamed Karam Allah Elkholy, Mohamed Ramadan, Abdelrahman Mohammed Elettreby, Ali Dway, Hatem Eldeeb, Abdullah Saeed Abujabal, David Hesketh Roberts

Cardiovascular Intervention and Therapeutics · 2025

DOI: 10.1007/s12928-025-01169-8 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Cardiovascular Intervention and Therapeutics, 2025. Verfasst von Basma Badrawy Khalefa und 11 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Ain Shams University, Cairo, Egypt. Hauptthemen laut MEDLINE: Aorta, Aortic Valve, Aortic Valve Stenosis, Heart Valve Prosthesis. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mansoura University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High aortic angulation (AA) can pose significant challenges during TAVR. This meta-analysis determines the impact of a horizontal aorta on TAVR outcomes with balloon-expandable (BEV) and self-expanding valves (SEVs). A comprehensive search was conducted from inception to June 2024. Thirteen observational studies assessing the impact of aortic angulation in patients undergoing TAVR replacement were included. The pooled results indicated that short-term mortality was significantly lower in patients with a non-horizontal aorta (RR = 0.76; 95% CI 0.62–0.95, P = 0.01). Subgroup analysis displayed that BEVs had a lower short-term mortality with a horizontal aorta than SEVs. The incidence of stroke was not significantly affected by aortic angulation with either valve type. However, the overall risk of permanent pacemaker implantation was lower in patients with a non-horizontal aorta for both valve types. Paravalvular regurgitation was also reduced in the non-horizontal aorta group, with no difference between aortic angulations in patients with BEVs. In contrast, SEVs favored a non-horizontal aorta in reducing paravalvular leak (RR = 0.66; 95% CI 0.46–0.94, P = 0.02). Both BEVs and SEVs show better results in patients with lower aortic root angulation. The increased incidence of conduction abnormalities and PPI rates with both valve types in patients with horizontal aorta is a concern. BEVs could be potentially used preferentially to SEVs in patients with a horizontal aorta as there was no difference between horizontal and non-horizontal aorta groups regarding short-term mortality, moderate-to-severe paravalvular leak, and need for a second valve.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AortaAortic ValveAortic Valve StenosisHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementHumansProsthesis DesignTreatment Outcome

Stichwörter der Autor:innen

Aortic angulationBEVSEVTAVR

Autor:innen und Institutionen

  • Faculty of Medicine, Ain Shams University, Cairo, Egypt.
  • Department of Medicine, Imperial College Healthcare NHS Trust, London, UK.
  • Faculty of Medicine, Cairo University, Cairo, Egypt.
  • Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
  • Faculty of Medicine, Aleppo University, Aleppo, Syria.
  • Faculty of Pharmacy, Zagazig University, Zagazig, Egypt.

Förderung

  • Mansoura University

Zitieren

APA

Khalefa, B. B., Gonnah, A. R., Yassin, M. N. A., Fayed, H., Arnaout, M., Elkholy, M. K. A., Ramadan, M., Elettreby, A. M., Dway, A., Eldeeb, H., Abujabal, A. S., & Roberts, D. H. (2025). Impact of aortic angulation on outcomes in transcatheter aortic valve replacement with balloon-expandable and self-expanding valves: a systematic review and meta-analysis. Cardiovascular Intervention and Therapeutics. https://doi.org/10.1007/s12928-025-01169-8

Vancouver

Khalefa BB, Gonnah AR, Yassin MNA, Fayed H, Arnaout M, Elkholy MKA, et al. Impact of aortic angulation on outcomes in transcatheter aortic valve replacement with balloon-expandable and self-expanding valves: a systematic review and meta-analysis. Cardiovascular Intervention and Therapeutics. 2025. doi:10.1007/s12928-025-01169-8

BibTeX
@article{Khalefa2025,
  author = {Khalefa, Basma Badrawy and Gonnah, Ahmed Reda and Yassin, Mazen Negmeldin Aly and Fayed, Hossam and Arnaout, Moumen and Elkholy, Mohamed Karam Allah and Ramadan, Mohamed and Elettreby, Abdelrahman Mohammed and Dway, Ali and Eldeeb, Hatem and Abujabal, Abdullah Saeed and Roberts, David Hesketh},
  title = {Impact of aortic angulation on outcomes in transcatheter aortic valve replacement with balloon-expandable and self-expanding valves: a systematic review and meta-analysis},
  journal = {Cardiovascular Intervention and Therapeutics},
  year = {2025},
  doi = {10.1007/s12928-025-01169-8}
}
Kostenlos starten →