Polyetheretherketone (PEEK)-based open tubular ion chromatography for perchlorate detection
Journal of Chromatography A · 2026
DOI: 10.1016/j.chroma.2026.466700 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2026. Verfasst von Jiafeng Pang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental Studies, China University of Geosciences, Wuhan, Hubei, 430078, China; Key Laboratory of Groundwater Quality and Health (Chin…. Hauptthemen laut MEDLINE: Perchlorates, Polyethylene Glycols, Water Pollutants, Chemical, Ketones. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Ministry of Education of the People's Republic of China, xinjiang shengchan jianshe bingtuan, Tarim University.
Abstract (Originalsprache)
Open tubular ion chromatography (OTIC) offers a lightweight, low-pressure and efficient platform for on-site ion analysis. Polyetheretherketone (PEEK) is an attractive column substrate because of its mechanical strength, chemical resistance and thermal stability, yet conventional sulfuric-acid sulfonation limits ion-exchange capacity and requires long preparation times. Here, a mixed methanesulfonic and sulfuric acid reagent followed by acetone rinsing was used to streamline the sulfonation process, producing a roughened inner surface with higher functional group density. The optimized 25 μm i.d. PEEK capillaries achieved a cation-exchange capacity of 2.5 ± 0.1 peq/mm2, roughly eight times higher than that from single-acid treatment. The latex-coated columns had an anion-exchange capacity of 20.0 ± 0.8 peq/mm2 and enabled baseline separation of perchlorate within 5 min using 6 mM sodium salicylate as the eluent. When integrated with a nonsuppressed OTIC system and electromembrane extraction, the method exhibited high reproducibility (RSD < 3%), a quantitation limit of 0.2 μM, and recoveries of 87.6-114.9% in environmental samples, confirming its reliability and sensitivity for perchlorate analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Environmental Studies, China University of Geosciences, Wuhan, Hubei, 430078, China; Key Laboratory of Groundwater Quality and Health (China University of Geosciences), Ministry of Education, Wuhan, Hubei, 430…
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China.
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China. Electronic address: zhangmin@guet.edu.cn.
Förderung
- Ministry of Education of the People's Republic of China
- xinjiang shengchan jianshe bingtuan
- Tarim University
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Ministry of Science and Technology of the People's Republic of China
Zitieren
APA
Pang, J., Zeng, Z., Zeng, H., Zhang, M., & Huang, W. (2026). Polyetheretherketone (PEEK)-based open tubular ion chromatography for perchlorate detection. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2026.466700
Vancouver
Pang J, Zeng Z, Zeng H, Zhang M, Huang W. Polyetheretherketone (PEEK)-based open tubular ion chromatography for perchlorate detection. Journal of Chromatography A. 2026. doi:10.1016/j.chroma.2026.466700
BibTeX
@article{Pang2026,
author = {Pang, Jiafeng and Zeng, Zihan and Zeng, Hui and Zhang, Min and Huang, Weixiong},
title = {Polyetheretherketone (PEEK)-based open tubular ion chromatography for perchlorate detection},
journal = {Journal of Chromatography A},
year = {2026},
doi = {10.1016/j.chroma.2026.466700}
}
EUVIMED