Enrichment of pyrethroid insecticides using effervescent-assisted ionic liquid functionalized in melamine sponge for pipette tip micro solid-phase extraction
Journal of Chromatography A · 2026-02 · 1769 · 466674
DOI: 10.1016/j.chroma.2026.466674 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2026-02. Verfasst von Dararat Saenkam und 2 weiteren Autor:innen. Beteiligte Einrichtung: Multidisciplinary Research Unit of Pure and Applied Chemistry (MRUPAC), Department of Chemistry and Center of Excellent for Innovation in Chemistry, …. Hauptthemen laut MEDLINE: Pyrethrins, Insecticides, Triazines, Ionic Liquids. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: Ministry of Higher Education, Science, Research and Innovation, Thailand, Center of Excellence for Innovation in Chemistry, Mahasarakham University.
Abstract (Originalsprache)
A preconcentration and detection method using ionic liquid for embedded in melamine sponge for pipette tip micro solid-phase extraction of pyrethroid insecticides coupled to HPLC was developed for trace amount of pyrethroids residue detection. The synthesis of ionic liquid was accomplished by using tributylhexadecylphosphonium bromide ([P44412]Br) and potassium hexafluorophosphate (KPF6), after that effervescent process was carried out by adding sodium carbonate into a centrifuge tube. The as-prepared ionic liquid was then embedded into melamine sponge, and used for pipette tip micro solid-phase extraction of insecticides in fruit juice matrices. After impregnation, the morphological and structural properties of the sorbents were characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR), respectively. Under the selected conditions, the method exhibited wide linear range (2 - 100 μg l-1) with a coefficient for determination (R2) greater than 0.99. The limit of quantification (LOQ) and limit of detection (LOD) were in the range of 2 - 3 μg l-1 and 0.7 - 1 μg l-1, respectively. Good reproducibility (RSD < 4.65%, n = 5) were achieved. Moreover, the proposed method provided high enrichment factors (EF) ranging from 36.50 to 45.52 folds. The sorbent was then applied to extract pyrethroids in fruit juice. Accuracy was excellent and acceptable recoveries were attained. The greenness profiles were evaluated utilizing multiple assessment metrics including the Analytical Eco-Scale, AGREE Assessment, and BAGI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Multidisciplinary Research Unit of Pure and Applied Chemistry (MRUPAC), Department of Chemistry and Center of Excellent for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham 44150, Thai…
- Department of Chemistry, Faculty of Science and Technology, Rajabhat Mahasarakham University, Maha Sarakham 44150, Thailand.
Förderung
- Ministry of Higher Education, Science, Research and Innovation, Thailand
- Center of Excellence for Innovation in Chemistry
- Mahasarakham University
Zitieren
APA
Saenkam, D., Suwannasom, P., & Vichapong, J. (2026). Enrichment of pyrethroid insecticides using effervescent-assisted ionic liquid functionalized in melamine sponge for pipette tip micro solid-phase extraction. Journal of Chromatography A, 1769, 466674. https://doi.org/10.1016/j.chroma.2026.466674
Vancouver
Saenkam D, Suwannasom P, Vichapong J. Enrichment of pyrethroid insecticides using effervescent-assisted ionic liquid functionalized in melamine sponge for pipette tip micro solid-phase extraction. Journal of Chromatography A. 2026;1769:466674. doi:10.1016/j.chroma.2026.466674
BibTeX
@article{Saenkam2026,
author = {Saenkam, Dararat and Suwannasom, Pirom and Vichapong, Jitlada},
title = {Enrichment of pyrethroid insecticides using effervescent-assisted ionic liquid functionalized in melamine sponge for pipette tip micro solid-phase extraction},