Sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent-based capsule phase microextraction device combined with HPLC/post-column derivatization for the determination of lanreotide, a human somatostatin analogue in urine
Journal of Chromatography A · 2024
DOI: 10.1016/j.chroma.2024.464674 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Marianna Ntorkou und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, GR, Thessaloniki 54124, Greece. Hauptthemen laut MEDLINE: Ionic Liquids, Liquid Phase Microextraction. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Aristotle University of Thessaloniki, Aristotle University of Thessaloniki Research Committee.
Abstract (Originalsprache)
In this research, a sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent-based capsule phase microextraction (CPME) device was developed in combination with liquid chromatography-post column derivatization for the first ever reported determination of a somatostatin analogue - lanreotide in human urine. The sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent was encapsulated in the lumen of a polypropylene capillary tube and characterized by FT-IR spectroscopy and SEM with energy dispersive X-ray spectroscopy (EDS). The main steps of the CPME workflow were optimized to obtain high extraction efficiency for the target analyte. After the separation of the analyte on a C8 stationary phase, the peptide was derivatized online with o-phthalaldehyde before the fluorescence detection. The main experimental parameters of CPME and the post-column procedures were systematically investigated and optimized. The method was validated in terms of selectivity, linearity, accuracy, precision, limits of detection (LOD), and limits of quantification (LOQ). The relative bias ranged between 88.8 and 115.6 % for the peptide, while the RSD values for repeatability and intermediate precision were less than 14.3 %. The achieved limit of detection (LOD) was 0.2 μΜ while the limit of quantitation (LOQ) was established as 0.9 μΜ. Finally, the sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent-based microextraction capsules were found to be reusable for at least 20 extractions. The developed method presented adequate overall performance, and it could be applied in the analysis of selected peptide in human urine samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, GR, Thessaloniki 54124, Greece.
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL, USA.
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR, 54124, Greece.
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, GR, Thessaloniki 54124, Greece. Electronic address: czacharis@pharm.auth.gr.
Förderung
- Aristotle University of Thessaloniki
- Aristotle University of Thessaloniki Research Committee
Zitieren
APA
Ntorkou, M., Kabir, A., Furton, K. G., Tzanavaras, P. D., & Zacharis, C. K. (2024). Sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent-based capsule phase microextraction device combined with HPLC/post-column derivatization for the determination of lanreotide, a human somatostatin analogue in urine. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.464674
Vancouver
Ntorkou M, Kabir A, Furton KG, Tzanavaras PD, Zacharis CK. Sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent-based capsule phase microextraction device combined with HPLC/post-column derivatization for the determination of lanreotide, a human somatostatin analogue in urine. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.464674
BibTeX
@article{Ntorkou2024,
author = {Ntorkou, Marianna and Kabir, Abuzar and Furton, Kenneth G and Tzanavaras, Paraskevas D and Zacharis, Constantinos K},
title = {Sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent-based capsule phase microextraction device combined with HPLC/post-column derivatization for the determination of lanreotide, a human somatostatin analogue in urine},
journal = {Journal of Chromatography A},
year = {2024},
doi = {10.1016/j.chroma.2024.464674}
}
EUVIMED