Combination of conventional and co-current countercurrent chromatography for the separation of compounds with very high partition coefficients
Journal of Chromatography A · 2025-08 · 1757 · 466104
DOI: 10.1016/j.chroma.2025.466104 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2025-08. Verfasst von Felix Rüttler und 1 weiteren Autor:innen. Beteiligte Einrichtung: University of Hohenheim, Institute of Food Chemistry, Department of Food Chemistry (170b), Garbenstraße 28, D-70599 Stuttgart, Germany. Hauptthemen laut MEDLINE: Countercurrent Distribution. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Countercurrent chromatography (CCC) is an instrumental liquid-liquid chromatographic method that separates analytes according to their partitioning between the stationary and mobile phases (Ksm value). CCC is valuable for the isolation of compounds in a biphasic solvent system, which provides Ksm values between 0.4 and 2.5. However, limitations exist for very high Ksm values, as this leads to long elution times and a high solvent consumption. Here, we show that these disadvantages can be overcome by a combination of conventional (CCC) and co-current (ccCCC) countercurrent chromatography. Specifically, separations were started in normal CCC mode followed by the fast elution in ccCCC mode (CCC+ccCCC). CCC+ccCCC experiments were performed with oleic acid methyl ester (18:1n-9-ME) and palmitic acid methyl ester (16:0-ME), which are difficult to separate by CCC and have Ksm values of >10 in n-hexane/acetonitrile (1:1, v/v). Tests with different switching times between CCC to ccCCC were used to determine the linear range of CCC+ccCCC runs, which was crucial for the separation efficiency and the stability of the solvent system. By combining simulated data with the obtained experimental data, it was possible to reliably predict chromatographic parameters in CCC+ccCCC mode. As a result, 18:1n-9-ME and 16:0-ME were sufficiently separated with CCC+ccCCC. The yield of pure 18:1n-9-ME and 16:0-ME was further improved by performing CCC+ccCCC in heart-cut mode. Given their reproducibility and predictability, the combination of normal CCC mode, followed by the ccCCC mode (CCC+ccCCC), represents a promising complement to existing approaches to make compounds with unfavorable Ksm values amenable to CCC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University of Hohenheim, Institute of Food Chemistry, Department of Food Chemistry (170b), Garbenstraße 28, D-70599 Stuttgart, Germany.
- University of Hohenheim, Institute of Food Chemistry, Department of Food Chemistry (170b), Garbenstraße 28, D-70599 Stuttgart, Germany. Electronic address: walter.vetter@uni-hohenheim.de.
Zitieren
APA
Rüttler, F., & Vetter, W. (2025). Combination of conventional and co-current countercurrent chromatography for the separation of compounds with very high partition coefficients. Journal of Chromatography A, 1757, 466104. https://doi.org/10.1016/j.chroma.2025.466104
Vancouver
Rüttler F, Vetter W. Combination of conventional and co-current countercurrent chromatography for the separation of compounds with very high partition coefficients. Journal of Chromatography A. 2025;1757:466104. doi:10.1016/j.chroma.2025.466104
BibTeX
@article{Rttler2025,
author = {Rüttler, Felix and Vetter, Walter},
title = {Combination of conventional and co-current countercurrent chromatography for the separation of compounds with very high partition coefficients},
journal = {Journal of Chromatography A},
year = {2025},
volume = {1757},
pages = {466104},
doi = {10.1016/j.chroma.2025.466104}
}
EUVIMED