EUVIMEDEUVIMED entdecken
Crossref

Automatic peak detection algorithm based on continuous wavelet transform for complex chromatograms from multi-detector micro-scale gas chromatographs

Xiangyu Zhao, Ryan Aridi, Jacob Hume, Swetha Subbiah, Xingqi Wu, Hyunwon Chung, Yutao Qin, Yogesh B Gianchandani

Journal of Chromatography A · 2024-01 · 1714 · 464582

DOI: 10.1016/j.chroma.2023.464582 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2024-01. Verfasst von Xiangyu Zhao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Computer Science, and Center for Wireless Integrated MicroSensing and Systems (WIMS(2)), University of Michi…. Hauptthemen laut MEDLINE: Wavelet Analysis, Algorithms. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Intelligence Advanced Research Projects Activity, Office of the Director of National Intelligence.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Peak detection for chromatograms, including the detection of peak retention times, peak start locations, and peak end locations, is an important processing step for extracting peak information that is used for chemical recognition. Compared to benchtop gas chromatographs, the chromatograms generated by microscale gas chromatographs (µGCs) often contain higher noise levels, peak overlap, peak asymmetry, and both positive and negative chromatographic peaks, increasing the challenges for peak detection. This paper reports an automatic peak detection algorithm based on continuous wavelet transform (CWT) for chromatograms generated by multi-detector µGCs. The relationship between chemical retention time and peak width is leveraged to differentiate chromatographic peaks from noise and baseline drift. Special features in the CWT coefficients are leveraged to detect peak overlap and asymmetry. For certain detectors that may generate positive and negative chromatographic peaks, the peaks cannot be independently detected reliably, but the peak information can be well extracted using peak information generated by other in-line single-polarity detectors. The implemented algorithm provided a true positive rate of 97.2 % and false discovery rate of 7.8 % for chromatograms generated by a µGC with three integrated detectors, two capacitive and one photoionization. The chromatograms included complex scenarios with positive and negative chromatographic peaks, up to five consecutive overlapping peaks, peak asymmetry factor up to 24, and signal-to-noise ratios spanning 9-2800.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wavelet AnalysisAlgorithmsChromatography, Gas

Stichwörter der Autor:innen

Baseline correctionCWTGCOverlapping peaksTailing

Autor:innen und Institutionen

  • Department of Electrical Engineering and Computer Science, and Center for Wireless Integrated MicroSensing and Systems (WIMS(2)), University of Michigan, Ann Arbor, MI 48109, USA.
  • Department of Electrical Engineering and Computer Science, and Center for Wireless Integrated MicroSensing and Systems (WIMS(2)), University of Michigan, Ann Arbor, MI 48109, USA. Electronic address: yutaoqin@umich.edu.
  • Department of Electrical Engineering and Computer Science, and Center for Wireless Integrated MicroSensing and Systems (WIMS(2)), University of Michigan, Ann Arbor, MI 48109, USA. Electronic address: yogesh@umich.edu.

Förderung

  • Intelligence Advanced Research Projects Activity
  • Office of the Director of National Intelligence

Zitieren

APA

Zhao, X., Aridi, R., Hume, J., Subbiah, S., Wu, X., Chung, H., Qin, Y., & Gianchandani, Y. B. (2024). Automatic peak detection algorithm based on continuous wavelet transform for complex chromatograms from multi-detector micro-scale gas chromatographs. Journal of Chromatography A, 1714, 464582. https://doi.org/10.1016/j.chroma.2023.464582

Vancouver

Zhao X, Aridi R, Hume J, Subbiah S, Wu X, Chung H, et al. Automatic peak detection algorithm based on continuous wavelet transform for complex chromatograms from multi-detector micro-scale gas chromatographs. Journal of Chromatography A. 2024;1714:464582. doi:10.1016/j.chroma.2023.464582

BibTeX
@article{Zhao2024,
  author = {Zhao, Xiangyu and Aridi, Ryan and Hume, Jacob and Subbiah, Swetha and Wu, Xingqi and Chung, Hyunwon and Qin, Yutao and Gianchandani, Yogesh B},
  title = {Automatic peak detection algorithm based on continuous wavelet transform for complex chromatograms from multi-detector micro-scale gas chromatographs},
  journal = {Journal of Chromatography A},
  year = {2024},
  volume = {1714},
  pages = {464582},
  doi = {10.1016/j.chroma.2023.464582}
}
Kostenlos starten →