EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance of a Smartphone-based Stool Test for Use in Colorectal Cancer Screening: Population-based Study

Michael Hoffmeister, Teresa Seum, Leopold Ludwig, Hermann Brenner

Clinical Gastroenterology and Hepatology · 2026-01 · 24 (1) · 241-249.e3

DOI: 10.1016/j.cgh.2025.04.027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Gastroenterology and Hepatology, 2026-01. Verfasst von Michael Hoffmeister und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany. Electronic address: m.hoffmeister@dk…. Hauptthemen laut MEDLINE: Colorectal Neoplasms, Smartphone, Early Detection of Cancer, Feces. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Forschung, Technologie und Raumfahrt, Deutsche Krebshilfe, Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND & AIMS: Noninvasive colorectal cancer (CRC) screening bears high potential for increasing participation if implemented in a straightforward way. We have evaluated the feasibility and diagnostic performance of a smartphone-based fecal immunochemical test (FIT) for CRC screening and compared its performance with a laboratory-based FIT. METHODS: Individuals scheduled for a screening colonoscopy in gastroenterology practices in Southern Germany enrolled into the BLITZ study between 2021 and 2023 were offered a smartphone-based FIT and a laboratory FIT. The smartphone-based FIT consists of a rapid test and a smartphone app. The app quantitatively evaluates the result of the rapid test using the smartphone camera. The feasibility of the smartphone-based FIT was evaluated in a self-administered questionnaire. The comparative performance of the 2 FITs was evaluated by sensitivity, specificity, and receiver-operator curve (ROC) measures. RESULTS: Of 654 study participants who were offered both a smartphone-based FIT in addition to the laboratory FIT, 361 (55%) made use of the smartphone-based FIT, 274 (76%) of those had a valid smartphone-based FIT, and 643 (98%) used the laboratory FIT. Overall, 89% considered the smartphone-based FIT as a useful alternative offer to the laboratory FIT. The reasons why the smartphone-based FIT was not used were mostly technical (app- or smartphone-related, 47%) or reflecting more general concerns or attitudes towards such a test (44%). The smartphone-based FIT showed a sensitivity for advanced neoplasms (28%; 95% confidence interval [CI], 13%-47%) similar to the laboratory FIT (34%; 95% CI, 18%-54%) at an identical specificity (92%; 95% CI, 87%-95%). CONCLUSIONS: The smartphone-based FIT could serve as an alternative in addition to currently offered laboratory FITs. STUDY REGISTRATION: German Clinical Trials Register (drks.de), Number: DRKS00008737.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Colorectal NeoplasmsSmartphoneEarly Detection of CancerFecesMass ScreeningHumansMaleFemaleMiddle AgedGermanyAgedSensitivity and SpecificityColonoscopyOccult BloodSurveys and QuestionnairesMobile ApplicationsFeasibility Studies

Stichwörter der Autor:innen

ColonoscopyDigital PreventionEarly DetectionFITSelf-test

Autor:innen und Institutionen

  • Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany. Electronic address: m.hoffmeister@dkfz.de.
  • Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany; Medical Faculty, Heidelberg University, Heidelberg, Germany.
  • Gastroenterology Practice, Dornstadt, Germany.
  • Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany; German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Heidelberg, Germany.

Förderung

  • Bundesministerium für Forschung, Technologie und Raumfahrt
  • Deutsche Krebshilfe
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Hoffmeister, M., Seum, T., Ludwig, L., & Brenner, H. (2026). Performance of a Smartphone-based Stool Test for Use in Colorectal Cancer Screening: Population-based Study. Clinical Gastroenterology and Hepatology, 24(1), 241-249.e3. https://doi.org/10.1016/j.cgh.2025.04.027

Vancouver

Hoffmeister M, Seum T, Ludwig L, Brenner H. Performance of a Smartphone-based Stool Test for Use in Colorectal Cancer Screening: Population-based Study. Clinical Gastroenterology and Hepatology. 2026;24(1):241-249.e3. doi:10.1016/j.cgh.2025.04.027

BibTeX
@article{Hoffmeister2026,
  author = {Hoffmeister, Michael and Seum, Teresa and Ludwig, Leopold and Brenner, Hermann},
  title = {Performance of a Smartphone-based Stool Test for Use in Colorectal Cancer Screening: Population-based Study},
  journal = {Clinical Gastroenterology and Hepatology},
  year = {2026},
  volume = {24},
  number = {1},
  pages = {241--249.e3},
  doi = {10.1016/j.cgh.2025.04.027}
}
Kostenlos starten →