EUVIMEDEUVIMED entdecken
Crossref

Misleading and avoidable: design-induced biases in observational studies evaluating cancer screening—the example of site-specific effectiveness of screening colonoscopy

Malte Braitmaier iD, Sarina Schwarz iD, Vanessa Didelez iD, Ulrike Haug iD

American Journal of Epidemiology · 2026

DOI: 10.1093/aje/kwaf069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Epidemiology, 2026. Verfasst von Malte Braitmaier und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biometry and Data Management, Leibniz Institute for Prevention Research and Epidemiology - BIPS, Bremen, Germany. Hauptthemen laut MEDLINE: Colonoscopy, Colorectal Neoplasms, Early Detection of Cancer, Observational Studies as Topic. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: BIPS..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Observational studies evaluating the effectiveness of cancer screening are often biased due to nonalignment at time zero, which can be avoided by target trial emulation (TTE). We aimed to illustrate this by evaluating site-specific effectiveness of screening colonoscopy regarding colorectal cancer (CRC) incidence. Based on a German health care database, we assessed the effect of screening colonoscopy vs no screening colonoscopy in preventing CRC in the distal and the proximal colon over 12 years of follow-up in 55-69-year-old persons. We compared four different study designs: cohort and case–control study, each with/without alignment at time zero. In both analyses with time zero-alignment, screening colonoscopy showed a rather similar effectiveness in reducing the incidence of distal and proximal CRC (cohort analysis: 32% (95% CI, 27%-37%) vs 28% (20%-35%); case–control analysis: 27% vs 33%). Both analyses without alignment suggested a difference by site: Incidence reduction regarding distal and proximal CRC, respectively, was 65% (61%-68%) vs 37% (31%-43%) in the cohort analysis and 77% (67%-84%) vs 46% (25%-61%) in the case–control analysis. Violations of basic design principles can substantially bias the results of observational studies. In our example, it falsely suggested a much stronger preventive effect of colonoscopy in the distal vs the proximal colon. Our study illustrates that TTE avoids such design-induced biases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColonoscopyColorectal NeoplasmsEarly Detection of CancerObservational Studies as TopicResearch DesignHumansMiddle AgedAgedMaleFemaleGermanyCase-Control StudiesBiasIncidenceMass Screening

Stichwörter der Autor:innen

cancer screeningcase–control studycohort studycolonoscopydistaleffectivenessproximaltarget trial emulation

Autor:innen und Institutionen

  • Department of Biometry and Data Management, Leibniz Institute for Prevention Research and Epidemiology - BIPS, Bremen, Germany.
  • Department of Clinical Epidemiology, Leibniz Institute for Prevention Research and Epidemiology - BIPS, Bremen, Germany.
  • Faculty of Mathematics and Computer Sciences, University of Bremen, Bremen, Germany.
  • Faculty of Human and Health Sciences, University of Bremen, Bremen, Germany.

ORCID-Profile: Malte Braitmaier, Sarina Schwarz, Vanessa Didelez, Ulrike Haug

Förderung

  • BIPS.

Zitieren

APA

Braitmaier, M., Schwarz, S., Didelez, V., & Haug, U. (2026). Misleading and avoidable: design-induced biases in observational studies evaluating cancer screening—the example of site-specific effectiveness of screening colonoscopy. American Journal of Epidemiology. https://doi.org/10.1093/aje/kwaf069

Vancouver

Braitmaier M, Schwarz S, Didelez V, Haug U. Misleading and avoidable: design-induced biases in observational studies evaluating cancer screening—the example of site-specific effectiveness of screening colonoscopy. American Journal of Epidemiology. 2026. doi:10.1093/aje/kwaf069

BibTeX
@article{Braitmaier2026,
  author = {Braitmaier, Malte and Schwarz, Sarina and Didelez, Vanessa and Haug, Ulrike},
  title = {Misleading and avoidable: design-induced biases in observational studies evaluating cancer screening—the example of site-specific effectiveness of screening colonoscopy},
  journal = {American Journal of Epidemiology},
  year = {2026},
  doi = {10.1093/aje/kwaf069}
}
Kostenlos starten →