Non-enzymatic square-wave voltammetric determination of progesterone using an MWCNT–IMZ composite
Clinica Chimica Acta · 2027-02 · 593 · 121302
DOI: 10.1016/j.cca.2026.121302 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2027-02. Verfasst von Suhaib Imtiyaz und 2 weiteren Autor:innen. Beteiligte Einrichtung: MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad 500078, Indi…. Hauptthemen laut MEDLINE: Progesterone, Nanotubes, Carbon, Electrochemical Techniques, Imidazoles. Die Arbeit nennt 52 Literaturangaben. Gefördert von: India Ministry of Science & Technology Department of Science and Technology.
Abstract (Originalsprache)
The growing need for rapid and accurate hormonal analysis has spurred the development of sensitive electrochemical sensing platforms for clinical diagnostics. This study presents a non-enzymatic electrochemical sensor constructed from a multi-walled carbon nanotube and 1-methylimidazole (MWCNT-IMZ) composite for the sensitive detection of progesterone (P4), a crucial biomarker in reproductive and hormonal disorders. The MWCNT-IMZ-modified electrode exhibited enhanced electron-transfer kinetics and an increased electroactive surface area, as confirmed by cyclic voltammetry using ferricyanide as a redox probe. The MWCNT-IMZ/SPE exhibited improved definition of the ferricyanide redox peak and reduced peak-to-peak separation compared with MWCNT/SPE, confirming enhanced interfacial electron-transfer characteristics. Square-wave voltammetry was used to quantitatively detect P4 over a range of 50-200 nM, with a limit of detection (LOD) of 13.3 nM and a limit of quantification (LOQ) of 44.2 nM. The proposed sensor demonstrated good reproducibility and stability, and its non-enzymatic design means that it does not require biological recognition elements or complex preconcentration steps. These results show that the developed sensing platform could be a simple, inexpensive, and compact tool for point-of-care hormonal testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad 500078, India; Department of Electrical and Electronics Engineering, Birla Institu…
Förderung
- India Ministry of Science & Technology Department of Science and Technology
Zitieren
APA
Imtiyaz, S., Amreen, K., & Goel, S. (2027). Non-enzymatic square-wave voltammetric determination of progesterone using an MWCNT–IMZ composite. Clinica Chimica Acta, 593, 121302. https://doi.org/10.1016/j.cca.2026.121302
Vancouver
Imtiyaz S, Amreen K, Goel S. Non-enzymatic square-wave voltammetric determination of progesterone using an MWCNT–IMZ composite. Clinica Chimica Acta. 2027;593:121302. doi:10.1016/j.cca.2026.121302
BibTeX
@article{Imtiyaz2027,
author = {Imtiyaz, Suhaib and Amreen, Khairunnisa and Goel, Sanket},
title = {Non-enzymatic square-wave voltammetric determination of progesterone using an MWCNT–IMZ composite},
journal = {Clinica Chimica Acta},
year = {2027},
volume = {593},
pages = {121302},
doi = {10.1016/j.cca.2026.121302}
}
EUVIMED