Investigating non-reproducible high-sensitivity cardiac troponin T results in real-world practice
Clinica Chimica Acta · 2027-02 · 593 · 121233
DOI: 10.1016/j.cca.2026.121233 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2027-02. Verfasst von Zeynep Şule Evren und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biochemistry, Başakşehir Çam and Sakura City Hospital, Istanbul, Türkiye. Electronic address: zeynepsule.evren@sbu.edu.tr. Hauptthemen laut MEDLINE: Troponin T. Die Arbeit nennt 31 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: High-sensitivity cardiac troponin T (hs-cTnT) testing is central to myocardial injury diagnosis, but non-reproducible ("outlier") results may complicate interpretation. Real-world data on their frequency and implications remain limited. We evaluated non-reproducible hs-cTnT results in our laboratory. METHODS: This retrospective study at Başakşehir Çam and Sakura City Hospital used hs-cTnT measurements from June 2023-December 2025. Non-reproducible results were identified by a critical difference (CD)-based approach applied to repeat testing of original serum and lithium-heparin plasma specimens on a Roche cobas e801 platform (fifth-generation assay). The common change criteria (3C) served as an alternative classifier. Chi-square tests compared outlier rates between serum and plasma and between URL-triggered and delta-triggered subgroups. Directional changes on repeat and additional turnaround time were also assessed. RESULTS: Among 10,815 repeated measurements, non-reproducible results occurred in 3.3% (n = 356; 95% CI 2.97-3.64). They were more frequent in plasma than in serum (5.4% vs. 0.7%, p < 0.001) and most common at initial concentrations of 10-20 ng/L (n = 223), followed by 20-30 ng/L (n = 92). Rates were 2.29% in URL-triggered and 3.87% in delta-triggered repeats (p < 0.001). On repeat, most results decreased (95.8%); increases were uncommon (4.2%). Repeat testing added a median delay of 42 min. The 3C criterion identified 425 results, comprising all CD-flagged cases plus 69 additional. CONCLUSIONS: Non-reproducible hs-cTnT results occur with appreciable frequency and may be influenced by sample matrix and concentration range. Most represent isolated elevations decreasing on repeat, potentially affecting workflow and time-sensitive decisions. Selective repeat testing with careful interpretation may preserve analytical reliability while minimizing delays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Biochemistry, Başakşehir Çam and Sakura City Hospital, Istanbul, Türkiye. Electronic address: zeynepsule.evren@sbu.edu.tr.
- Department of Medical Biochemistry, Başakşehir Çam and Sakura City Hospital, Istanbul, Türkiye. Electronic address: kamiltaha.ucar@sbu.edu.tr.
Zitieren
APA
Evren, Z. Ş., & Uçar, K. T. (2027). Investigating non-reproducible high-sensitivity cardiac troponin T results in real-world practice. Clinica Chimica Acta, 593, 121233. https://doi.org/10.1016/j.cca.2026.121233
Vancouver
Evren ZŞ, Uçar KT. Investigating non-reproducible high-sensitivity cardiac troponin T results in real-world practice. Clinica Chimica Acta. 2027;593:121233. doi:10.1016/j.cca.2026.121233
BibTeX
@article{Evren2027,
author = {Evren, Zeynep Şule and Uçar, Kamil Taha},
title = {Investigating non-reproducible high-sensitivity cardiac troponin T results in real-world practice},
journal = {Clinica Chimica Acta},
year = {2027},
volume = {593},
pages = {121233},
doi = {10.1016/j.cca.2026.121233}
}